文献速递临床免疫质量管理与危急值

四种间接法建立成人血清IgG性别与年龄特异性参考区间的比较

Comparison of four indirect methods for establishing sex- and age-specific reference intervals for IgG: based on real world data.
PubMed 文献 · Clin Chim Acta · 2025-06-08

基于北京医院2020至2021年13,162条血清IgG实测数据,比较四种间接法建立成人性别与年龄特异性参考区间。四种方法所得参考区间男女间差异显著,随年龄增长上限升高、下限降低,季节无明显趋势。Hoffmann与RefineR法的上限符合基于国家行业标准参考区间的允许差异,建议临床实验室建立自己的参考区间。

要点

  • 四种间接法所得血清IgG参考区间在男女间存在显著差异。
  • 随年龄增长,IgG参考区间上限升高、下限降低。
  • Hoffmann与RefineR法上限符合基于国家行业标准的允许差异。

核心结论

  • 基于真实世界数据用四种间接法建立了成人血清IgG的性别与年龄特异性参考区间。
  • 男女之间及年轻与年长人群之间存在显著差异,临床实验室应建立自己的参考区间。

研究设计与样本

  • 收集北京医院2020至2021年全部血清IgG测定结果,经数据筛选后共获得13,162条数据。
  • 对总人群、不同性别、年龄和季节(月份)分别用四种间接法计算参考区间。
  • 以参考区间CV的最小允许偏倚和德国临床化学与检验医学学会(DGKL)阐述的允许差异(pD)为准则,与厂商参考区间及中国国家行业标准比较。

主要发现

  • 四种方法计算的参考区间在男女之间均有显著差异。
  • 随年龄增长,参考区间上限(URL)升高、下限(LRL)降低。
  • 不同季节间无明显趋势。
  • 四种方法的LRL均在基于厂商参考区间的pD内。
  • Hoffmann与RefineR法的URL符合基于国家行业标准参考区间的pD。

关键数值与推荐

  • 共获得13,162条血清IgG数据。
  • 四种方法的LRL均在基于厂商参考区间的pD内。
  • Hoffmann与RefineR法的URL符合基于国家行业标准参考区间的pD。
  • 国家行业标准与厂商参考区间均不在本研究参考区间CV的最小允许偏倚内。

临床怎么用

  • 临床实验室应基于本实验室真实世界数据建立自己的血清IgG参考区间,以更好诊断和治疗疾病。
  • 建立参考区间时应考虑性别和年龄差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare four indirect methods for establishing sex- and age-specific reference intervals (RI) for adult serum immunoglobulin G (IgG) based on real world data. METHODS: All serum IgG measurement results from 2020 to 2021 in Beijing Hospital were collated. Following data screening, four indirect methods were applied to calculate the RI of the total population, different sexes, ages and seasons (months). The results were then compared with the manufacturer's RI and National Industry Standard in China to verify the reliability of the RI obtained in this study. The minimal allowable bias of the CV of the RI and the permissible difference (pD) elaborated by the German Society for Clinical Chemistry and Laboratory Medicine (DGKL) were used as the criterion. RESULTS: A total of 13,162 data points were obtained. There were significant differences between men and women within the RI calculated by four methods. With increasing age, the upper limit of RI (URL) increased and the lower limit reference (LRL )decreased. However, there was no obvious trend in different seasons. The LRL of the four methods were within the pD based on manufacturer's RI, while the URL of the Hoffmann and RefineR methods conformed to the pD based on the National Industry Standard's RI, and neither the RI of the National Industry Standard nor the manufacturer's were within the minimal allowable bias of the CV of the RI with our study. CONCLUSIONS: The serum IgG RI were established by four indirect method. The significant differences were found between males and females, younger and older. Clinical laboratories should establish their own RI in order to better diagnose and treat disease.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Liu W, Xie Z, Wang M, et al. Comparison of four indirect methods for establishing sex- and age-specific reference intervals for IgG: based on real world data. Clin Chim Acta. 2025. PMID: 40494430. doi:10.1016/j.cca.2025.120420

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。