肺边缘区淋巴瘤伴单克隆冷凝球蛋白对胆红素检测的干扰
本研究报道一例肺边缘区淋巴瘤患者伴高浓度单克隆IgG型蛋白及明显凝胶形成,该蛋白可干扰临床生化检测。通过比较单克隆IgG与多克隆免疫球蛋白的总胆红素检测曲线、干扰实验及稀释消除实验,发现M蛋白对胆红素检测的干扰与其浓度正相关且具有M蛋白特异性。ROC分析显示,在GLB≥31.9 g/L亚组中,联合曲线指标的AUC为0.852。
要点
- 肺MZL患者可伴高浓度单克隆IgG蛋白并干扰总胆红素检测。
- M蛋白对胆红素检测的干扰呈浓度依赖性且具M蛋白特异性。
- GLB≥31.9 g/L亚组联合曲线指标AUC为0.852,有助筛查。
核心结论
- 肺边缘区淋巴瘤患者的高浓度单克隆IgG型蛋白可特异性干扰总胆红素检测,干扰程度与M蛋白浓度正相关。
研究设计与样本
- 病例报道结合实验研究,比较单克隆IgG蛋白与多克隆免疫球蛋白的总胆红素检测曲线差异,并进行干扰实验和稀释消除实验。
- 采用R和EmpowerStat统计系统分析血清单克隆蛋白与总胆红素吸光度曲线数据的相关性。
主要发现
- 单克隆IgG蛋白对胆红素检测的干扰与其浓度呈正相关,且不同于多克隆免疫球蛋白的干扰。
- 多因素分析显示球蛋白(GLB)与平方根转换后的曲线光密度(OD)数据呈非线性相关。
- ROC曲线分析显示,GLB≥31.9 g/L亚组使用联合曲线指标的AUC为0.852。
关键数值与推荐
- GLB≥31.9 g/L亚组联合曲线指标的AUC为0.852。
临床怎么用
- 有助于加强临床M蛋白筛查,科学评估需进行血清蛋白电泳检测的人群,降低M蛋白人群的漏诊率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Marginal zone lymphoma (MZL) of the lung is an indolent B-cell lymphoma. The peripheral blood of most patients with pulmonary MZL contains low or undetectable monoclonal immunoglobulin (M protein) levels. In this case, the clinical laboratory discovered that the pulmonary MZL patient not only associated with high concentration of monoclonal IgG-type protein but also exhibited obvious gel formation characteristics that interfered with clinical biochemistry tests. Thus, the role of M protein in total bilirubin determination was examined in this study. Total bilirubin detection curve difference comparison between monoclonal IgG protein and polyclonal immunoglobulin, interference experiments, and dilution elimination experiments were conducted. These experiments revealed not only a positive correlation between M protein interference in bilirubin detection with its concentration, but also M protein-specific interference distinct from polyclonal immunoglobulin. We employed the R and EmpowerStat statistical systems to evaluate the correlation between serum monoclonal protein and total bilirubin absorbance curve data. Multivariate analysis revealed a nonlinear correlation between with globulin (GLB) and square root transformed curve optical density (OD) data. The receiver operating characteristic (ROC) curve analysis indicated an area under the curve (AUC) of 0.852 for the GLB ≥ 31.9 g/L subgroup using combined curve indicators. Our findings can enhance clinical M protein screening and scientific assessment of the populations requiring serum protein electrophoresis testing, thereby reducing the rate of missed diagnoses in the M protein population.
引用
- Li Y, Zhou L, Wang K, et al. An interference in bilirubin detection: Pulmonary marginal zone lymphoma presenting monoclonal cryoglobulin. Clin Chim Acta. 2024. PMID: 39647570. doi:10.1016/j.cca.2024.120066
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。