凝血管中常规临床生化分析物的预处理稳定性:居家样本采集适用性探讨
研究采集9名患者凝血管血样,分别立即处理及20°C、37°C储存48小时后处理,检测18项常规生化及PSA、CEA,按生物学变异分析性能规范评估质量。CEA、PSA、CRP、肌酐、HDL胆固醇、甘油三酯和γGT回收率在理想偏倚要求内,葡萄糖、电解质、ALT和AST超出最低偏倚标准。钠、氯、钾、钙和肝酶在凝血血样延迟48小时处理时不够稳定,而CEA、PSA、CRP、肌酐和甘油三酯足够稳定。
要点
- 凝血管血样延迟48小时处理时,钠、氯、钾、钙和肝酶不够稳定。
- CEA、PSA、CRP、肌酐和甘油三酯在延迟48小时处理后足够稳定。
- 葡萄糖、电解质、ALT和AST回收率超出最低偏倚标准。
核心结论
- 钠、氯、钾、钙和肝酶在凝血血样延迟48小时处理时不够稳定,而CEA、PSA、CRP、肌酐和甘油三酯足够稳定。
研究设计与样本
- 从9名患者采集三支凝血管,一支立即处理,另两支分别20°C和37°C储存48小时后处理。
主要发现
- CEA、PSA、CRP、肌酐、HDL胆固醇、甘油三酯和γGT的回收率在理想偏倚要求内。
- 葡萄糖、所有纳入的电解质、ALT和AST的回收率超出最低偏倚标准。
关键数值与推荐
- 采用基于生物学变异的分析性能规范判定样本质量。
- 每个分析物按回收率与偏倚标准比较确定质量水平。
临床怎么用
- 居家自采血样运输延迟时,应考虑钠、氯、钾、钙和肝酶的不稳定性。
- CEA、PSA、CRP、肌酐和甘油三酯在48小时延迟处理下仍可提供可靠结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: There is a growing interest in self-collection of blood for clinical applications. Next to allowing patients to self-sample blood, adequate sample stability of the analyte is essential to provide an accurate and reliable test result. This is particularly important for self-collected blood, as the transport of the sample to the clinical laboratory will generally require significantly more time than routine blood samples collected by healthcare professionals, and under less controlled circumstances. METHODS: Three additional blood collection tubes (coagulation tubes) were collected from nine patients; one was processed immediately, the second and third were processed after 48 h of storage at 20 °C and 37 °C, respectively. The collected serum was stored at -20 °C and samples collected from individual patients were analyzed in the same analytical run for 18 routine chemistry analytes and the tumor markers PSA and CEA. The recoveries obtained after delayed processing were quantified and the quality of the sample for each analyte was determined using the analytical performance specifications based on biological variation. RESULTS: For each analyte, the quality level of samples with delayed processing was determined. For the CEA, PSA, CRP, creatinine, HDL-cholestrol, triglycerides and yGT the recovery was within the desirable bias requirement. Recovery for glucose, all included electrolytes, ALT and AST exceeded the minimum bias criterion. CONCLUSIONS: Several analytes including sodium, chloride, potassium, calcium, and liver enzymes were not, while others; CEA, PSA, CRP, creatinine and triglycerides, were found to be sufficiently stable in coagulated blood, when processed with a delay of 48 h.
引用
- Roelofs M, Ramkisoensing K, Even R, et al. Pre-processing stability of routine clinical chemistry analytes in a clotting tube; investigating the (un)suitability for at-home sample collection. Clin Chim Acta. 2024. PMID: 39528066. doi:10.1016/j.cca.2024.120035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。