生殖器外自采样检测淋病和衣原体的可行性研究:扩展退伍军人健康管理局性传播感染筛查
本研究为多中心多平台验证研究,纳入9个站点,比较自采样与临床医生采样生殖器外标本对沙眼衣原体(CT)和淋病奈瑟菌(NG)的检测性能。共分析2324项检测(直肠501份、口咽661份),自采样灵敏度直肠CT 94.44%、NG 100%,口咽CT 100%、NG 97.22%,特异性高,阴性预测值达100%。自采样有望克服性传播感染筛查障碍。
要点
- 自采样生殖器外标本检测CT/NG具有高灵敏度和特异性,阴性预测值100%。
- 直肠自采样灵敏度CT 94.44%、NG 100%;口咽自采样灵敏度CT 100%、NG 97.22%。
- 自采样可提供便捷、以患者为中心的替代方案,扩展筛查覆盖。
核心结论
- 自采样生殖器外标本用于CT/NG检测具有高灵敏度和特异性,阴性预测值100%,可克服筛查障碍。
研究设计与样本
- 多中心多平台验证研究,作为国家退伍军人健康管理局病理与实验室医学质量改进项目,9个站点参与,自采样与临床医生采样同时采集,以临床医生采样为金标准。
主要发现
- 共分析2324项检测,其中直肠501份、口咽661份。
- 直肠标本自采样灵敏度CT 94.44%、NG 100%,特异性CT和NG均为99%。
- 口咽标本自采样灵敏度CT 100%、NG 97.22%,特异性CT 99.85%、NG 99.36%。
- 阴性预测值为100%。
关键数值与推荐
- 自采样生殖器外CT/NG检测灵敏度:直肠CT 94.44%、NG 100%;口咽CT 100%、NG 97.22%。
- 特异性:直肠CT和NG均为99%;口咽CT 99.85%、NG 99.36%。
- 阴性预测值100%。
临床怎么用
- 可考虑采用自采样生殖器外标本进行CT/NG核酸检测,以扩大无症状高危人群的性传播感染筛查。
局限性
- 自采样生殖器外样本目前尚未获得美国食品药品监督管理局任何核酸扩增检测平台的批准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Rectal and pharyngeal infections with gonorrhea and chlamydia are of concern because they are associated with higher risk of HIV acquisition. Extragenital screening in asymptomatic persons at high risk may have the potential to reduce the incidence of these sexually transmitted infections (STIs). Several testing platforms are available for the testing of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) using nucleic acid amplification tests (NAATs). Self-collected extragenital samples are currently not approved by the US Food and Drug Administration in any NAAT platform. This study compares the analytical performance of self-collected extragenital specimens to that of clinician-collected specimens. METHODS: We performed a multicenter/multiplatform validation study as a National Veterans Health Administration Pathology and Laboratory Medicine quality improvement project, with 9 different participating sites. Self-collected specimens were obtained at the same time as clinician-collected specimens. Clinician-collected specimens were used as the gold standard to evaluate the sensitivity and specificity of self-collection. RESULTS: A total of 2324 individual tests were analyzed (501 rectal and 661 oropharyngeal). The sensitivity was 94.44% for CT and 100% for NG for rectal specimens, whereas it was 100% for CT and 97.22% for NG for oral specimens. Specificity for oral specimens was 99.85% for CT and 99.36% for NG, whereas for rectal specimens, it was 99% for CT and NG. CONCLUSIONS: Self-collected specimens for extragenital CT/NG testing are highly sensitive and specific, with negative predictive values of 100%. Self-collection has the potential to overcome a major barrier for STI screening by providing an accessible, convenient, and patient-centered alternative.
引用
- Navas ME, Musoke L, Van Epps P, et al. Extragenital self-collection testing for gonorrhea and chlamydia: A feasibility study for expanding STI screening in the Veterans Health Administration. Am J Clin Pathol. 2025. PMID: 39394953. doi:10.1093/ajcp/aqae135
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。