文献速递临床生化质量管理与危急值

稳定胸苷激酶1四聚体提升血清水平定量质量控制

A stable thymidine kinase 1 tetramer for improved quality control of serum level quantification.
PubMed 文献 · Clin Chim Acta · 2024-09-19

本研究在大肠杆菌系统中表达含四聚体卷曲螺旋肽的重组胸苷激酶1(TK1)四聚体蛋白,优化诱导条件提高表达量、功能性和溶解度。尺寸排阻色谱确认形成分子量127.2 KDa的四聚体,ELISA显示其对anti-TK1 IgY亲和力高于野生型TK1,且加热、冻融和冻干后几乎无免疫活性损失。提示重组TK1四聚体可作为诊断试剂盒校准品,用于临床实验室和体外诊断试剂的质量控制。

要点

  • 重组TK1四聚体分子量为127.2 KDa,经尺寸排阻色谱确认四聚体结构。
  • TK1四聚体对anti-TK1 IgY的亲和力高于野生型TK1。
  • TK1四聚体经加热、冻融和冻干后几乎无免疫活性损失。

核心结论

  • 重组TK1四聚体有潜力作为诊断检测试剂盒的校准品,成为临床实验室和体外诊断试剂质量控制的候选物质。

研究设计与样本

  • 研究在大肠杆菌系统中表达含四聚体卷曲螺旋肽的重组TK1四聚体蛋白,并优化诱导条件。

主要发现

  • 优化诱导条件后,蛋白表达水平、功能性和溶解度显著提高。
  • 尺寸排阻色谱确认表达的重组TK1蛋白形成四聚体结构,分子量为127.2 KDa。
  • ELISA实验显示TK1四聚体与anti-TK1 IgY的亲和力高于野生型TK1。
  • TK1四聚体对加热、冻融和冻干表现出良好稳定性,几乎无免疫活性损失。

临床怎么用

  • 重组TK1四聚体可作为校准品用于诊断检测试剂盒,支持临床实验室和体外诊断试剂的质量控制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

DNA synthesis is a critical process for cell growth and division. In cancer patients, an enzyme called thymidine kinase 1 (TK1) is often elevated in the blood, making it a valuable biomarker for cancer diagnosis and treatment. However, previous studies have shown that recombinant TK1 can exist in unstable mixtures of tetramers and dimers, leading to inconsistent results and potentially affecting accuracy. To address this issue, we hypothesized that incorporating tetrameric coiled-coil peptides could enhance TK1 self-assembly into stable tetramers without requiring additional adenosine triphosphate. In this study, we successfully expressed a recombinant TK1 tetramer protein in the Escherichia coli system. We optimized the induction conditions, significantly increasing protein expression levels, functionality, and solubility. Size exclusion chromatography confirmed the formation of a tetrameric structure in the expressed TK1 protein, with a molecular weight of 127.2 KDa, consistent with our expectations. We also found that the TK1 tetramer exhibited higher affinity with anti-TK1 IgY than wild-type TK1, as shown by enzyme-linked immunosorbent assay experiments. Moreover, the TK1 tetramer demonstrated good stability against heating, freeze-thawing and lyophilization with almost no immunoactivity lost. These findings suggest that recombinant TK1 tetramers have the potential to serve as calibrators in diagnostic assay kits, becoming promising candidates for quality control of clinical laboratory and in vitro diagnostic reagents.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Feng X, Zhang J, Liu J, et al. A stable thymidine kinase 1 tetramer for improved quality control of serum level quantification. Clin Chim Acta. 2024. PMID: 39304108. doi:10.1016/j.cca.2024.119967

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。