文献速递临床免疫

化学发光微阵列免疫法检测儿童蛋清过敏的评估

Detection of egg white allergy in children by specific IgE microarray chemiluminescence immunoassay.
PubMed 文献 · Clin Chim Acta · 2024-09-13

该研究评估全自动化学发光微阵列免疫法(CLMIA)检测儿童过敏原特异性IgE的性能,并与Phadia系统比对。优化后LOD低于0.01 kU/L,批内精密度<10%,批间<15%,交叉污染率<0.5%,与Phadia阳性符合率>90%、阴性>85%、Kappa>0.8,显示CLMIA在儿童过敏原检测中具有良好临床应用潜力。

要点

  • CLMIA检测过敏原sIgE的LOD低于0.01 kU/L,线性范围0.1-100.0 kU/L。
  • 批内精密度<10%,批间<15%,交叉污染率<0.5%。
  • 与Phadia系统阳性符合率>90%,阴性>85%,Kappa>0.8。

核心结论

  • CLMIA在儿童过敏原检测尤其是多组分检测中具有应用前景。

研究设计与样本

  • 使用儿童血清样本验证CLMIA检测过敏原的准确性和可靠性,并评估其临床诊断实用性。

主要发现

  • 优化后过敏原LOD低于0.01 kU/L。
  • 各组分在0.1-100.0 kU/L范围内线性良好,R2>0.99。
  • 批内精密度<10%,批间<15%,交叉污染率<0.5%。
  • 与Phadia系统阳性符合率>90%,阴性符合率>85%,Kappa>0.8。

关键数值与推荐

  • LOD低于0.01 kU/L。
  • 线性范围0.1-100.0 kU/L,R2>0.99。
  • 批内精密度<10%,批间<15%。
  • 交叉污染率<0.5%。
  • 与Phadia系统阳性符合率>90%,阴性符合率>85%,Kappa>0.8。

临床怎么用

  • CLMIA可用于儿童过敏原sIgE的自动化检测,尤其适合多组分同时检测。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Allergen testing has emerged as a pivotal component in prevention and treatment strategies for allergic diseases among children and the utilization of specific IgE (sIgE) through a fully automated chemiluminescent microarray immunoassay (CLMIA) has emerged as a promising trend in the simultaneous detection of multiple allergenic components of children. METHODS: The accuracy and reliability of CLMIA were verified using children's serum samples that concentrated on allergens. the allergens. The clinical diagnostic practicability of CLMIA was assessed through comprehensive evaluations including measurements of the limit of detection (LOD), intra-batch, and inter-batch precision, linearity analysis, the cross-contamination rate, and the concordance rate with the Phadia system. RESULTS: After the optimization process of CLMIA, the LODs for allergens were calculated to be below 0.01 kU/L, demonstrating the high sensitivity of CLMIA. All components exhibited good linearity within the range of 0.1-100.0 kU/L and the coefficient of determinations (R2 > 0.99). The data of intra-batch precision (<10 %) and inter-batch data (<15 %) illustrated the high reproducibility of CLMIA. The cross-contamination rates for allergens (<0.5 %) showed the high accuracy of CLMIA without interfering. The positive concordance rate between CLMIA and the Phadia system exceeds 90 % with a good negative concordance rate (>85 %) and the Kappa coefficients (>0.8), suggesting the close alignment of CLMIA and the Phadia system and showing the satisfactory clinical potential of CLMIA in children's allergy disease. CONCLUSIONS: The application of CLMIA has been promising in allergen testing, especially for detecting multiple allergenic components in children.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Zhang RW, Yuan DD, Yang X, et al. Detection of egg white allergy in children by specific IgE microarray chemiluminescence immunoassay. Clin Chim Acta. 2024. PMID: 39278524. doi:10.1016/j.cca.2024.119966

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。