健康个体血清1,25-二羟维生素D、甲状旁腺激素和血浆成纤维细胞生长因子23的生物学变异
该研究纳入16名健康受试者,连续7周采集血清和血浆EDTA样本,用DiaSorin Liaison平台化学发光免疫分析法双份检测,评估1,25(OH)2D、PTH 1-84和iFGF23的个体内和个体间生物学变异,并按EFLM-BV模型计算分析质量规范。首次报道1,25(OH)2D的BV估计值,并改进iFGF23和PTH 1-84的现有BV数据。
要点
- 1,25(OH)2D的CVI为22.2%(95%CI 18.9-26.4),CVG为21.2%(95%CI 14.2-35.1)。
- iFGF23的CVI为16.1%(95%CI 13.5-19.5),CVG为21.1%(95%CI 14.5-35.8)。
- PTH 1-84的CVI为17.9%(95%CI 14.8-21.8),CVG为31.1%(95%CI 22.1-50.8)。
核心结论
- 首次报道1,25(OH)2D的生物学变异估计值,并通过先进免疫测量方法改进iFGF23和PTH 1-84的现有BV数据。
研究设计与样本
- 纳入16名健康受试者,连续7周采集血清和血浆EDTA样本,在DiaSorin Liaison平台用化学发光免疫分析法双份检测。
- 方差验证后,采用标准ANOVA或CV-ANOVA评估个体内(CVI)和个体间(CVG)生物学变异,并按EFLM-BV模型计算分析质量规范。
主要发现
- 1,25(OH)2D的CVI为22.2%(95%CI 18.9-26.4),CVG为21.2%(95%CI 14.2-35.1)。
- iFGF23的CVI为16.1%(95%CI 13.5-19.5),CVG为21.1%(95%CI 14.5-35.8)。
- PTH 1-84的CVI为17.9%(95%CI 14.8-21.8),CVG为31.1%(95%CI 22.1-50.8)。
关键数值与推荐
- 1,25(OH)2D的CVI为22.2%(95%CI 18.9-26.4),CVG为21.2%(95%CI 14.2-35.1)。
- iFGF23的CVI为16.1%(95%CI 13.5-19.5),CVG为21.1%(95%CI 14.5-35.8)。
- PTH 1-84的CVI为17.9%(95%CI 14.8-21.8),CVG为31.1%(95%CI 22.1-50.8)。
临床怎么用
- 这些BV数据可用于定义分析质量规范、评估参考区间的 usefulness 以及判断同一个体连续测量变化的显著性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Measuring 1,25-dihydroxyvitamin D (1,25(OH)2D), parathyroid hormone 1-84 (PTH 1-84) and intact FGF23 (iFGF23) is crucial for diagnosing a variety of diseases affecting bone and mineral homeostasis. Biological variability (BV) data are important for defining analytical quality specifications (APS), the usefulness of reference intervals, and the significance of variations in serial measurements in the same subject. The aim of this study was to pioneer the provision of BV estimates for 1,25(OH)2D and to improve existing BV estimates for iFGF23 and PTH 1-84. MATERIALS AND METHODS: Serum and plasma-EDTA samples of sixteen healthy subjects have been collected for seven weeks and measured in duplicate by chemiluminescent immunoassay on the DiaSorin Liaison platform. After variance verification, within-subject (CVI) and between-subject (CVG) BV estimates were assessed by either standard ANOVA, or CV-ANOVA. The APSs were calculated according to the EFLM-BV-model. RESULTS: We found the following CVI estimates with 95% confidence intervals:1,25(OH)2D, 22.2% (18.9-26.4); iFGF23, 16.1% (13.5-19.5); and PTH 1-84, 17.9% (14.8-21.8). The CVG were: 1,25(OH)2D, 21.2% (14.2-35.1); iFGF23, 21.1% (14.5-35.8); and PTH 1-84, 31.1% (22.1-50.8). CONCLUSIONS: We report for the first time BV estimates for 1,25(OH)2D and enhance existing data about iFGF23-BV and PTH 1-84-BV through cutting-edge immunometric methods.
引用
- Iannone F, Angotti E, Lucia F, et al. The biological variation of serum 1,25-dihydroxyvitamin D and parathyroid hormone, and plasma fibroblast growth factor 23 in healthy individuals. Clin Chim Acta. 2024. PMID: 38471629. doi:10.1016/j.cca.2024.117863
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。