文献速递临床免疫临床生化质量管理与危急值

化学发光免疫法检测滑液LTF和S100A8诊断假体周围关节感染

Detection of synovial fluid LTF and S100A8 by chemiluminescence immunoassay for the diagnosis of periprosthetic joint infection.
PubMed 文献 · Clin Chim Acta · 2023-04-29

本研究建立了自动化化学发光免疫分析法(CLIA)检测滑液乳铁蛋白(LTF)和S100钙结合蛋白A8(S100A8),并评估其分析性能。在86例全关节置换术后疑似假体周围关节感染(PJI)患者中检测滑液,LTF和S100A8诊断PJI的AUC分别为0.954(95%CI:0.909-0.999)和0.958(95%CI:0.918-0.997)。

要点

  • 建立的CLIA法检测LTF线性范围20-10,000 ng/mL,S100A8为5-5000 ng/mL。
  • CLIA法精密度、特异性和回收率符合行业标准。
  • 滑液LTF和S100A8对PJI具有高效诊断潜力。

核心结论

  • 建立的CLIA法具有自动化、高通量、低价优势,有望临床推广。
  • 通过CLIA检测滑液LTF和S100A8对预测和诊断PJI具有高效诊断潜力。

研究设计与样本

  • 开发滑液LTF和S100A8的化学发光免疫分析法(CLIA)并评估分析性能。

主要发现

  • LTF检测系统线性范围20-10,000 ng/mL,S100A8检测系统线性范围5-5000 ng/mL。
  • 精密度、特异性和回收率等性能参数符合行业标准。

关键数值与推荐

  • 在86例疑似PJI患者中,滑液LTF诊断PJI的AUC为0.954(95%CI:0.909-0.999)。
  • 滑液S100A8诊断PJI的AUC为0.958(95%CI:0.918-0.997)。

临床怎么用

  • 可采用CLIA法检测滑液LTF和S100A8辅助诊断PJI。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Synovial fluid lactoferrin (LTF) and S100 calcium-binding protein A8 (S100A8) have been considered as potential biomarkers for the diagnosis of periprosthetic joint infection (PJI) through our previous research. However, the detection methods of these two proteins are still immature, so a rapid, accurate and cost-effective testing method is warranted. MATERIALS AND METHODS: We developed chemiluminescent immunoassays (CLIA) for the automated detection of synovial fluid LTF and S100A8 and assessed the analytical performance for these two methods. In addition, we recruited 86 patients who were suspected of PJI after total joint replacement (TJA) and examined their synovial fluid using CLIA to explore the clinical application value of these methods and the diagnostic efficiency of synovial fluid LTF and S100A8 for PJI. RESULTS: Our established CLIA methods have a wide linear range of 20-10,000 ng/mL for LTF detection system and 5-5000 ng/mL for S100A8 detection system. Performance parameters such as precision, specificity, and recovery rate can meet the industry standards. Then, the established methods were used to detect LTF and S100A8 in synovial fluid samples, which showed excellent diagnostic efficiency for PJI, and the areas under ROC curve (AUC) were 0.954 (95 % CI: 0.909-0.999) and 0.958 (95 % CI: 0.918-0.997), respectively. CONCLUSION: Our established CLIA methods have the advantages of automation, high throughput, low price, and is expected to be widely popularized in clinical applications. Synovial fluid LTF and S100A8 detected through CLIA had efficient diagnostic potentiality for predicting and diagnosing PJI.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Xu Y, Hu C, Liu J, et al. Detection of synovial fluid LTF and S100A8 by chemiluminescence immunoassay for the diagnosis of periprosthetic joint infection. Clin Chim Acta. 2023. PMID: 37127230. doi:10.1016/j.cca.2023.117369

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。