文献速递临床免疫分子诊断

第四代和第五代HIV-1/HIV-2抗原/抗体检测的信号/临界值比值和抗原指数在急性HIV感染诊断中的效用:实时用于立即启动抗逆转录病毒治疗的可适用性

Utility of the Signal-to-Cutoff Ratio and Antigen Index from Fourth- and Fifth-Generation HIV-1/HIV-2 Antigen/Antibody Assays for the Diagnosis of Acute HIV Infection: Applicability for Real-Time Use for Immediate Initiation of Antiretroviral Therapy.
PubMed 文献 · J Clin Microbiol · 2022-11-30

该研究回顾了127例第四代ARCHITECT和第五代Bio-Plex免疫分析结果阳性但确认性抗体检测阴性或不确定的患者,其中38例确诊急性HIV感染,89例为假阳性。ROC曲线显示S/CO比值和抗原指数(AI)的AUC分别为0.970和0.968,S/CO阈值3.78时灵敏度96.3%、特异性93.4%,AI阈值2.83时灵敏度100%、特异性96.4%。S/CO比值与病毒载量显著相关(Spearman相关系数0.486,P=0.014),而AI不相关。在确认性NAAT结果可用前,审查S/CO比值或AI可提高急性HIV感染诊断的准确性。

要点

  • S/CO比值阈值3.78诊断急性HIV感染的灵敏度96.3%、特异性93.4%。
  • 抗原指数(AI)阈值2.83时灵敏度100%、特异性96.4%。
  • S/CO比值与病毒载量显著相关(r=0.486,P=0.014),AI不相关。

核心结论

  • 在确认性NAAT结果不可及时,审查S/CO比值或抗原指数可提高急性HIV感染诊断准确性。

研究设计与样本

  • 回顾性分析127例第四代ARCHITECT和第五代Bio-Plex免疫分析阳性但确认性抗体检测阴性或不确定的患者,其中38例确诊急性HIV感染,89例假阳性。

主要发现

  • S/CO比值的AUC为0.970(95%CI 0.935-1.00),抗原指数的AUC为0.968(95%CI 0.904-1.00)。
  • S/CO比值阈值3.78时灵敏度96.3%、特异性93.4%;抗原指数阈值2.83时灵敏度100%、特异性96.4%。
  • S/CO比值与病毒载量显著相关(Spearman相关系数0.486,P=0.014),抗原指数与病毒载量不相关。
  • 病毒载量中位数>2.8百万拷贝/mL。
  • 观察到两例假阳性结果的抗原指数和S/CO比值显著高于中位数,提示可发生生物学假阳性。

关键数值与推荐

  • S/CO比值阈值3.78:灵敏度96.3%,特异性93.4%。
  • 抗原指数阈值2.83:灵敏度100%,特异性96.4%。

临床怎么用

  • 在确认性NAAT结果可用前,可审查S/CO比值或抗原指数以辅助急性HIV感染诊断,支持立即启动抗逆转录病毒治疗。

局限性

  • 回顾性研究,样本量有限,需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Identification of individuals with acute HIV infection (AHI) and rapid initiation of antiretroviral therapy (ART) are priorities for HIV elimination efforts. Fourth- and fifth-generation HIV-1/HIV-2 antigen (Ag)/antibody (Ab) combination assays can quickly identify patients with AHI, but false-positive results can occur. Confirmatory nucleic acid amplification testing (NAAT) may not be rapidly available. We reviewed the data for 127 patients with positive fourth-generation ARCHITECT and fifth-generation Bio-Plex immunoassay results who had negative or indeterminate confirmatory Ab testing results, which yielded 38 patients with confirmed AHI and 89 patients with false-positive results. The receiver operating characteristic (ROC) curves showed excellent discriminatory power, with an area under the curve (AUC) for the signal-to-cutoff (S/CO) ratio of 0.970 (95% confidence interval [CI], 0.935 to 1.00) and an AUC for the Ag index (AI) of 0.968 (95% CI, 0.904 to 1.00). A threshold of 3.78 for the S/CO ratio would maximize the sensitivity (96.3%) and specificity (93.4%). The threshold for AI was 2.83 (sensitivity of 100% and specificity of 96.4%). The S/CO ratio was significantly correlated with the viral load (Spearman correlation coefficient, 0.486 [P = 0.014]), but the AI was not. The viral loads were all high, with a median of >2.8 million copies/mL. Two false-positive results with AI and S/CO ratio values markedly higher than the medians were observed, indicating that biological false-positive results can occur. Review of the S/CO ratio or AI may be used to improve the accuracy of AHI diagnosis prior to confirmatory NAAT results being available.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Whitney E, Pitrak D, Beavis KG, et al. Utility of the Signal-to-Cutoff Ratio and Antigen Index from Fourth- and Fifth-Generation HIV-1/HIV-2 Antigen/Antibody Assays for the Diagnosis of Acute HIV Infection: Applicability for Real-Time Use for Immediate Initiation of Antiretroviral Therapy. J Clin Microbiol. 2022. PMID: 36448814. doi:10.1128/jcm.01204-22

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。