载脂蛋白B48能否用于乳糜性积液的诊断?
本研究首次评估乳糜微粒特异性标志物载脂蛋白B48(apoB48)对乳糜性积液的诊断价值,采用化学发光夹心酶免疫法测定积液残样中apoB48水平,并与甘油三酯检测及金标准脂蛋白电泳比较。结果显示乳糜性积液患者积液甘油三酯、apoB48及甘油三酯/胆固醇比值显著升高,apoB48诊断价值可能至少与甘油三酯检测相当,但需更大样本验证。
要点
- 乳糜性积液患者积液apoB48、甘油三酯及甘油三酯/胆固醇比值显著升高。
- apoB48诊断乳糜性积液的AUC为0.84(95%CI 0.72–0.96),甘油三酯为0.80(0.67–0.94)。
- apoB48是乳糜性积液诊断的有前景标志物,尚需更大样本研究确认。
核心结论
- apoB48似乎是诊断乳糜性积液的有前景标志物,其可能的诊断改善需在更大规模研究中确认。
研究设计与样本
- 本研究采用化学发光夹心酶免疫法测定送至实验室用于乳糜微粒检测和脂质测定的积液残样中apoB48水平。
- 研究将apoB48和甘油三酯检测的诊断价值与金标准方法(脂蛋白电泳分离)进行比较。
主要发现
- 乳糜性积液患者积液中的甘油三酯、apoB48水平及甘油三酯/胆固醇比值显著高于非乳糜性积液患者。
- apoB48诊断乳糜性积液的受试者工作特征曲线下面积(95%CI)为0.84(0.72,0.96),甘油三酯为0.80(0.67,0.94)。
关键数值与推荐
- apoB48用于最大Youden指数的阈值为2.45 µg/mL。
- apoB48用于灵敏度>95%的阈值为0.25 µg/mL。
- apoB48用于特异度>95%的阈值为19.00 µg/mL。
临床怎么用
- 对于疑似乳糜性积液,可考虑检测积液apoB48作为辅助诊断指标,但其临床价值尚需更大样本研究确认。
局限性
- 本研究为首次评估apoB48诊断乳糜性积液价值的研究,样本量可能有限,结论需更大规模研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Chylous effusions such as chylothorax, chylopericardium and chylous ascites are marked by the abnormal presence of chylomicrons in serous membranes. These relatively rare situations are associated with high morbidity and mortality rates. Given that a macroscopic assessment of the fluid is insufficient, the current gold standard method for chylous effusion is the electrophoretic separation of lipoproteins. Serous effusions are most frequently assayed for triglycerides, with a diagnostic threshold varying between studies. The present study is the first to assess the value of the apolipoprotein B48, specific of the chylomicron, in the diagnosis of chylous effusions. METHODS: A chemiluminescent sandwich enzyme immunoassay was used to measure levels of apoB48 in remnant samples of effusion fluid sent to our laboratory for chylomicron detection and lipid assays. The diagnostic values of apoB48 and triglyceride assays were compared with that of the gold standard method. RESULTS: The triglyceride and apoB48 levels and the triglyceride/cholesterol ratio in the effusion fluid were significantly higher in patients with chylous effusion. The threshold values for apoB48 were respectively 2.45, 0.25 and 19.00 µg/mL for a maximal Youden index, a sensitivity > 95 %, and a specificity > 95 %. The apoB48 assay's diagnostic value might be at least as high as that of a triglyceride assay (area under the receiver operating characteristic curve [95 % confidence interval]: 0.84 [0.72, 0.96]) and 0.80 [0.67, 0.94], respectively). CONCLUSION: ApoB48 appears to be a promising marker for the diagnosis of chylous effusions; the putative diagnostic improvement must be confirmed in larger studies.
引用
- Lefrère B, Sakka M, Fourati S, et al. Could the chylomicron marker apoB48 be of value in the diagnosis of chylous effusions? Clin Chim Acta. 2022. PMID: 36463939. doi:10.1016/j.cca.2022.11.022
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。