常规使用厌氧血培养瓶可提高微生物检出率并缩短阳性报警时间

Routine Use of Anaerobic Blood Culture Bottles for Specimens Collected from Adults and Children Enhances Microorganism Recovery and Improves Time to Positivity.
PubMed 文献 · J Clin Microbiol · 2022-08-30

该研究评估了 BacT/Alert Virtuo 系统常规使用厌氧瓶(FN Plus)与需氧瓶(FA Plus)的临床效用,共纳入 158,710 瓶标本。厌氧瓶检出 403 株专性厌氧菌,若仅用需氧瓶则除 8 株外均漏检;金黄色葡萄球菌在厌氧瓶中检出更多且平均阳性报警时间更短。结论支持常规纳入厌氧瓶进行血培养采集。

要点

  • 厌氧瓶可检出绝大多数专性厌氧菌,仅用需氧瓶会漏检。
  • 金黄色葡萄球菌在厌氧瓶中检出率更高且阳性报警时间更短。
  • 仅采集需氧瓶会显著减少阳性培养数和分离菌株数。

核心结论

  • 常规纳入厌氧瓶进行血培养采集可提高微生物检出率并改善阳性报警时间。

研究设计与样本

  • 在 BacT/Alert Virtuo 血培养系统上评估厌氧瓶(FN Plus)与需氧瓶(FA Plus)的临床效用,共纳入 2018 年 11 月至 2019 年 10 月期间的 158,710 瓶标本。

主要发现

  • 6,652 个阳性厌氧瓶中有 384 瓶(5.8%)含 403 株专性厌氧菌;小于 19 岁患者中 389 个阳性厌氧瓶中有 15 瓶(1.8%)含 16 株专性厌氧菌。
  • 若未使用厌氧瓶,除 8 株专性厌氧菌外其余均无法检出。
  • 金黄色葡萄球菌在厌氧瓶中检出 1,992 瓶,需氧瓶 1,901 瓶,差异有统计学意义(P = 0.009);平均阳性报警时间厌氧瓶 1,138 min,需氧瓶 1,174 min(P = 0.027)。
  • 仅 25 种微生物在需氧瓶中检出率和/或阳性报警时间显著优于厌氧瓶,提示厌氧瓶对大多数菌种提供可比生长。
  • 若仅采集需氧瓶,将减少 2,027 个阳性培养和 7,452 株分离菌报告,包括金黄色葡萄球菌(413 株,减少 10.6%)、铜绿假单胞菌(9 株,减少 3.1%)和大肠埃希菌(193 株,减少 14.0%)。

临床怎么用

  • 建议血培养采集时常规包含厌氧瓶,尤其对于成人及儿童患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The utility of anaerobic blood culture bottles remains controversial, especially for specimens from children. Data are limited on the inclusion of an anaerobic bottle as part of a blood culture "set" when using contemporary blood culture instruments and media. Here, we evaluated the clinical utility of anaerobic blood culture bottles (FN Plus) and aerobic bottles (FA Plus) for the BacT/Alert Virtuo blood culture system (bioMérieux). A total of 158,710 bottles collected between November 2018 and October 2019 were evaluated. There were 6,652 positive anaerobic bottles, of which 384 (5.8%) contained 403 obligate anaerobes. In patients <19 years old, there were 389 positive anaerobic bottles, with 15 (1.8%) containing 16 obligate anaerobes. If not for anaerobic bottles, all but 8 obligate anaerobes would have gone undetected. Furthermore, anaerobic bottles were advantageous for some facultative anaerobes. Staphylococcus aureus from anaerobic bottles demonstrated statistically significant increased recovery (1,992 anaerobic versus 1,901 aerobic bottles, P = 0.009) and faster mean time to positivity (1,138 versus 1,174 min, P = 0.027). Only 25 microorganisms had statistically significant improved recovery and/or faster time to positivity from aerobic versus anaerobic bottles, suggesting anaerobic bottles offer comparable growth for most species. Finally, if only an aerobic bottle had been collected, 2,027 fewer positive cultures would have been detected and 7,452 fewer isolates would have been reported, including cultures with S. aureus (413 isolates, 10.6% less), Pseudomonas aeruginosa (9 isolates, 3.1% less) and Escherichia coli (193 isolates, 14.0% less). Taken together, these findings support the practice of routinely including an anaerobic bottle for blood culture collection.

来源:J Clin Microbiol,查看原文。版权归原作者所有。

引用

  1. Ransom EM, Burnham CD. Routine Use of Anaerobic Blood Culture Bottles for Specimens Collected from Adults and Children Enhances Microorganism Recovery and Improves Time to Positivity. J Clin Microbiol. 2022. PMID: 36040158. doi:10.1128/jcm.00500-22

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。