文献速递临床免疫质量管理与危急值

以人O型红细胞为指示系统检测循环免疫复合物活性的方法建立与临床应用

Establishment and clinical application of an assay for the activity of circulating immune complexes using human O-erythrocytes as an indicator system.
PubMed 文献 · Clin Chim Acta · 2022-07-03

该研究建立了一种以人O型红细胞为指示系统、通过溶血程度定量补体激活型循环免疫复合物(ACIC)活性的实验室检测方法。结果显示溶血程度指数OD值与ACIC呈负相关(r=-0.986,P=0.002),批内和批间CV分别为6.5%和8.1%,并建议男性HD参考范围56-88、女性51-86。健康者与自身免疫病患者HD差异显著(P=0.001),患者HD较低反映ACIC较强。

要点

  • 溶血程度HD与ACIC活性呈负相关,HD越低提示ACIC越强。
  • 该方法批内CV 6.5%、批间CV 8.1%,稳定性良好。
  • 建议HD参考范围男性56-88、女性51-86,性别差异显著(P=0.015)。

核心结论

  • 以人O型红细胞为指示系统的ACIC检测方法灵敏、准确,具有临床应用潜力。

研究设计与样本

  • 方法学研究:以血清CIC激活补体,剩余补体通过致敏人O型红细胞激活,以溶血程度定量ACIC。
  • 每个血清样本连续检测十天以评估稳定性,并纳入健康个体和自身免疫病患者进行ACIC测定。

主要发现

  • 溶血程度指数OD值与ACIC呈负相关(r=-0.986,P=0.002)。
  • 批内和批间CV分别为6.5%和8.1%。
  • 男女HD差异显著(P=0.015),两性均符合正态分布。
  • 健康者与自身免疫病患者血清HD差异显著(P=0.001),患者HD较低。

关键数值与推荐

  • HD计算公式:HD=(检测值OD/阴性值OD)*100。
  • 推荐HD参考范围:男性56-88,女性51-86。

临床怎么用

  • 可用于实验室检测补体激活型循环免疫复合物活性,辅助评估自身免疫病相关免疫复合物水平。
  • 结果判读需注意性别差异,并按推荐参考范围分别解读男女HD值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop a suitable clinical laboratory assay for detecting the activity of circulating immune complexes (CICs) that activate complement (ACIC). METHODS: CICs measured in serum were initially used to activate complement, and the remaining complement was activated through sensitized human O-erythrocytes. ACIC was quantified by the degree of hemolysis. Each serum sample was tested for ten consecutive days to determine its stability. Reference ranges are suggested. ACIC was measured in both healthy individuals and patients with autoimmune diseases as well. RESULTS: The OD values of the hemolysis degree index were inversely proportional to ACIC (r = -0.986, P = 0.002). A pooled serum was used to eliminate interference and optimize the experiment. The hemolysis degree (HD) was used to indicate the detection result. HD = (detection value OD/negative value OD)*100. Both the intra-batch and the inter-batch results showed good stability with a CV of 6.5% and 8.1%, respectively. HD differences between males and females were significant (P = 0.015) while the normal distribution for both genders was conformed. The HD recommended reference range for men is 56-88 while for women is 51-86. Serum HD of healthy subjects and autoimmune disease patients showed a significant difference (P = 0.001). Autoimmune disease patients have lower HD which was a result of having stronger ACIC. CONCLUSION: The ACIC assay while utilizing human O-erythrocytes as an indicator system is sensitive and accurate, and has potential in clinical applications.

来源:Clin Chim Acta,查看原文。版权归原作者所有。

引用

  1. Ding X, Liu L, Yang G, et al. Establishment and clinical application of an assay for the activity of circulating immune complexes using human O-erythrocytes as an indicator system. Clin Chim Acta. 2022. PMID: 35787990. doi:10.1016/j.cca.2022.06.023