文献速递临床生化质量管理与危急值

探索尿液渗透压替代指标:自动化机器学习方法

Searching for the urine osmolality surrogate: an automated machine learning approach.
PubMed 文献 · Clin Chem Lab Med · 2022-07-04

包含电导率和比密等参数的模型R²为0.70-0.83,70-84%结果落在最小允许偏差24.17%范围内。AutoML工具可促进临床实验室机器学习模型开发。

要点

  • 电导率和比密是估算尿液渗透压的最重要变量。
  • 结合电导率与其他尿液参数的机器学习模型R²达0.70-0.83。
  • 70-84%的模型预测结果落在最小允许偏差24.17%以内。

核心结论

  • 结合尿液电导率与其他尿液分析参数并用经验证的机器学习模型,可产生有前景的尿液渗透压替代指标。

主要发现

  • AutoML引擎共开发183个机器学习模型。
  • 电导率和比密具有最高的变量重要性。
  • 包含电导率、比密及其他尿液分析参数的模型R²为0.70-0.83,70-84%的结果落在最小允许偏差24.17%范围内。

关键数值与推荐

  • 最小允许偏差24.17%来自生物学变异数据,用作一致性限。

临床怎么用

  • AutoML工具可促进机器学习开发周期,应考虑在临床实验室中用于开发机器学习模型。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Automated machine learning (AutoML) tools can help clinical laboratory professionals to develop machine learning models. The objective of this study was to develop a novel formula for the estimation of urine osmolality using an AutoML tool and to determine the efficiency of AutoML tools in a clinical laboratory setting. METHODS: Three hundred routine urinalysis samples were used for reference osmolality and urine clinical chemistry analysis. The H2O AutoML engine completed the machine learning development steps with minimum human intervention. Four feature groups were created, which include different urinalysis measurements according to the Boruta feature selection algorithm. Method comparison statistics including Spearman's correlation, Passing-Bablok regression analysis were performed, and Bland Altman plots were created to compare model predictions with the reference method. The minimum allowable bias (24.17%) from biological variation data was used as the limit of agreement. RESULTS: The AutoML engine developed a total of 183 ML models. Conductivity and specific gravity had the highest variable importance. Models that include conductivity, specific gravity, and other urinalysis parameters had the highest R2 (0.70-0.83), and 70-84% of results were within the limit of agreement. CONCLUSIONS: Combining urinary conductivity with other urinalysis parameters using validated machine learning models can yield a promising surrogate. Additionally, AutoML tools facilitate the machine learning development cycle and should be considered for developing ML models in clinical laboratories.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Topcu Dİ, Bayraktar N. Searching for the urine osmolality surrogate: an automated machine learning approach. Clin Chem Lab Med. 2022. PMID: 35778953. doi:10.1515/cclm-2022-0415

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。