全国HLA分型NGS能力验证计划结果
我国建立HLA-NGS分型能力验证计划,向24家实验室发放覆盖11个HLA基因座的10份DNA参考物质,要求至少报告HLA-A、HLA-B、HLA-C、HLA-DRB1、HLA-DQB1和HLA-DPB1六个基因座。
要点
- 全部等位基因总符合率99.2%(3390/3420),Ⅱ类不一致率高于Ⅰ类。
- 分型错误与测序覆盖度不足和等位基因判读错误有关。
核心结论
- 该能力验证结果提示开展HLA-NGS分型的临床实验室需定期参加外部质量评估。
- 分型错误反映NGS用于HLA分型的薄弱环节,对相关实验室质量改进有参考意义。
研究设计与样本
- 我国建立HLA-NGS能力验证计划,向24家参与实验室发放11个HLA基因座的10份DNA参考物质。
- 要求参与实验室提交至少HLA-A、HLA-B、HLA-C、HLA-DRB1、HLA-DQB1和HLA-DPB1六个基因座的NGS分型结果。
- 同时收集各实验室的样本制备方法、NGS平台和分型软件信息。
主要发现
- 全部HLA等位基因总符合率为99.2%(3390/3420)。
- Ⅰ类基因座总体不一致率为0.2%(3/1440),Ⅱ类基因座为1.4%(27/1980)。
- 对分型错误进一步分析提示测序覆盖度不足和等位基因判读错误。
临床怎么用
- 临床HLA-NGS分型实验室应定期参加外部质量评估以保障分型可靠性。
- 应关注测序覆盖度不足与等位基因判读错误等薄弱环节并持续改进。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Accurate human leucocyte antigen (HLA) typing is essential for solid organ transplantation (SOT) and hematopoietic stem cell transplantation (HSCT). Next-generation sequencing (NGS) is increasingly adopted by clinical laboratories performing HLA typing. To ensure reliable NGS-based HLA typing throughout China, a HLA-NGS proficiency testing (PT) scheme was set up. METHODS: A panel of 10 DNA reference materials for 11 HLA loci were distributed to 24 participants. They were asked to submit NGS typing results for at least six loci including HLA-A, HLA-B, HLA-C, HLA-DRB1, HLA-DQB1, and HLA-DPB1. Information regarding individual laboratory's sample preparation method, NGS platform, and genotyping software was also collected. RESULTS: Thirteen participants correctly identified HLA alleles in all samples. The total concordance rate for all HLA alleles typed was 99.2% (3390/3420). The overall discordance was 0.2% (3/1440) for Class I, and 1.4% (27/1980) for Class II loci. Further investigation of the typing mistakes pointed to poor sequencing coverage and wrong allele calls. The errors identified reflect the deficient aspect of NGS in HLA typing, which may have implications for quality improvement for relevant laboratories. CONCLUSIONS: The results of this PT underscore the necessity of regular participation in external quality assessment for clinical laboratories that perform HLA-NGS typing.
引用
- Lin G, Zhang K, Li J, et al. A national proficiency scheme for human leucocyte antigen typing by next-generation sequencing. Clin Chim Acta. 2022. PMID: 35738456. doi:10.1016/j.cca.2022.06.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。