定量自身抗体检测的批内与批间变异数据库:欧洲多中心研究
共分析686个批内CV和1331个批间CV,发现CV显著取决于免疫分析方法、IQC水平和性质,抗体水平低于阳性阈值2倍时精密度更差,商业IQC的CV低于患者来源IQC,15次测量足以建立可靠的批内和批间变异。
要点
- 自身抗体定量检测的批内和批间CV与免疫分析方法、IQC水平和性质显著相关。
- 抗体水平低于阳性阈值2倍时,检测不精密度更高。
- 商业IQC的CV低于患者来源IQC,15次测量可建立可靠变异。
核心结论
- 本研究首次提供了定量自身抗体检测批内和批间变异的国际数据库,可用于ISO 15189认可要求并帮助临床诊断实验室保证患者结果质量。
研究设计与样本
- 分析对象为15种不同自身抗体的定量检测批内和批间变异,共分析686个批内CV值和1331个批间CV值。
主要发现
- 批内和批间CV均显著依赖于免疫分析方法、IQC水平和IQC性质。
- 抗体水平低于阳性阈值2倍时,观察到更高的不精密度。
- 商业IQC的CV低于患者来源IQC。
- 自身抗体类型对检测性能影响较小,15次测量足以建立可靠的批内和批间变异。
临床怎么用
- 临床诊断实验室可参考该数据库中的批内和批间变异值,用于ISO 15189认可和质量保证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: No reference data are available on repositories to measure precision of autoantibody assays. The scope of this study was to document inter- and intra-run variations of quantitative autoantibody assays based on a real-world large international data set. METHODS: Members of the European Autoimmunity Standardisation Initiative (EASI) group collected the data of intra- and inter-run variability obtained with assays quantifying 15 different autoantibodies in voluntary participating laboratories from their country. We analyzed the impact on the assay performances of the type of immunoassay, the number of measurements used to calculate the coefficient of variation (CVs), the nature and the autoantibody level of the internal quality control (IQC). RESULTS: Data were obtained from 64 laboratories from 15 European countries between February and October 2021. We analyzed 686 and 1,331 values of intra- and inter-run CVs, respectively. Both CVs were significantly dependent on: the method of immunoassay, the level of IQC with higher imprecision observed when the antibody levels were lower than 2-fold the threshold for positivity, and the nature of the IQC with commercial IQCs having lower CVs than patients-derived IQCs. Our analyses also show that the type of autoantibody has low impact on the assay' performances and that 15 measurements are sufficient to establish reliable intra- and inter-run variations. CONCLUSIONS: This study provides for the first time an international repository yielding values of intra- and inter-run variation for quantitative autoantibody assays. These data could be useful for ISO 15189 accreditation requirements and will allow clinical diagnostic laboratories to assure quality of patient results.
引用
- Dragon-Durey MA, Bizzaro N, Senant M, et al. Repository of intra- and inter-run variations of quantitative autoantibody assays: a European multicenter study. Clin Chem Lab Med. 2022. PMID: 35749077. doi:10.1515/cclm-2022-0411
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。