文献速递质量管理与危急值临床生化临床血液与体液

带固定机制的气动管道运输载体原型自动化卸载评估

Evaluation of a pneumatic tube system carrier prototype with fixing mechanism allowing for automated unloading.
PubMed 文献 · Clin Chem Lab Med · 2022-05-31

研究比较了Aerocom®新型气动管道运输载体原型(可自动固定9支采血管)与传统载体及人工快递运输对血液样本质量的影响。35名受试者的三重复血样(肝素锂、EDTA、枸橼酸钠各1管)随机分配至三种运输方式,检测51项临床化学、血液学和凝血指标。49项指标在三组间一致性良好,溶血敏感指标钾无显著差异,LDH和游离血红蛋白在快递与两种载体间有统计学显著偏移但临床影响可忽略。

要点

  • 新型载体原型与传统载体及快递运输间49/51项检测指标一致性良好。
  • 钾等溶血敏感指标在三种运输方式间无统计学显著差异。
  • LDH和游离血红蛋白有统计学显著偏移,但临床影响可忽略。

核心结论

  • Aerocom®载体原型适用于诊断血液样本的运输,且通过减少病房和实验室手工操作时间及降低载体包装错误风险改善整体工作流程。

研究设计与样本

  • 研究纳入35名受试者,每人采集三重复血样(1管肝素锂、1管EDTA、1管枸橼酸钠),随机分配至快递运输、传统载体(AD160)和载体原型三种方式。
  • 运输后检测51项临床化学、血液学和凝血指标并进行比较。

主要发现

  • 51项检测指标中49项在三种运输方式间一致性良好,尤其是传统载体与载体原型之间。
  • 钾在三种运输方式间无统计学显著差异。
  • LDH和游离血红蛋白在快递与两种载体类型间显示统计学显著偏移,但临床影响可忽略。
  • 游离血红蛋白中位浓度:快递运输0.29 g/L(18 µmol/L),传统载体0.31 g/L(19 µmol/L),载体原型0.32 g/L(20 µmol/L)。
  • 游离血红蛋白最小差异(MD)为0.052 g/L(3.23 µmol/L),该浓度下差异无法通过分析分辨。

临床怎么用

  • 载体原型可用于诊断血液样本的气动管道运输,有助于减少病房和实验室手工操作时间并降低载体包装错误风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: A carrier prototype by Aerocom® (Schwäbisch Gmünd, Germany) for pneumatic tube systems (PTS) is able to transport 9 blood tubes which are automatically fixed by closing the lid. In this study, we examined the influence of the transport on blood sample quality using the carrier prototype comparing to courier transport and a conventional carrier (AD160, Aerocom®). METHODS: Triplicate blood samples sets (1 lithium heparin, 1 EDTA, 1 sodium citrate) of 35 probands were split among the transportation methods: 1. courier, 2. conventional carrier, and 3. carrier prototype. After transport 51 measurands from clinical chemistry, hematology and coagulation were measured and compared. RESULTS: Overall, 49 of the investigated 51 measurands showed a good concordance among the three transport types, especially between the conventional carrier and the carrier prototype. Focusing on well-known hemolysis sensitive measurands, potassium showed no statistically significant differences. However, between courier and both carrier types lactate dehydrogenase (LDH) and free hemoglobin (fHb) showed statistically significant shifts, whereas the clinical impact of the identified differences was neglectable. The median concentration of fHb, for example, was 0.29 g/L (18 µmol/L), 0.31 g/L (19 µmol/L) and 0.32 g/L (20 µmol/L) for courier transport, conventional carrier and carrier prototype, respectively. These differences cannot be resolved analytically since the minimal difference (MD) for fHb is 0.052 g/L (3.23 µmol/L), at this concentration. CONCLUSIONS: The carrier prototype by Aerocom® is suitable for transportation of diagnostic blood samples. The overall workflow is improved by decreasing hands-on-time on the ward and laboratory while minimizing the risk of incorrectly packed carriers.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Märtens CM, Schöpfel J, Bollmann S, et al. Evaluation of a pneumatic tube system carrier prototype with fixing mechanism allowing for automated unloading. Clin Chem Lab Med. 2022. PMID: 35635785. doi:10.1515/cclm-2022-0193

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。