基于微球的多重免疫检测用于HIV、病毒性肝炎、梅毒和疱疹的多分析物筛查与监测
研究开发了一种基于Luminex Magpix平台的10重免疫检测,可同时检测HIV-1、HIV-2、梅毒螺旋体、HBV、HCV、HSV-1和HSV-2的IgG抗体。使用417份特征明确的样本评估,总体敏感性92.2%、特异性98.1%,与参考检测的总体一致率为96.7%,kappa值0.91。该检测通量高、样本量小,有望简化疾病监测。
要点
- 10重免疫检测可同时检测HIV-1/2、梅毒、HBV、HCV、HSV-1/2的IgG抗体。
- 总体敏感性92.2%、特异性98.1%,与参考检测一致率96.7%。
- 各病原体敏感性68.7–100%、特异性95.6–100%,kappa 0.69–1.00。
核心结论
- 基于Luminex微球的10重免疫检测性能良好,可用于多种病原体抗体同时筛查与血清监测。
研究设计与样本
- 研究开发了基于Luminex Magpix平台的10重免疫检测,通过偶联特异性抗原检测血浆或血清中的IgG抗体。
- 使用417份特征明确的样本评估检测性能,样本含HIV-1、HIV-2、梅毒螺旋体、HBV、HCV、HSV-1和HSV-2抗体。
主要发现
- 多重检测总体敏感性为92.2%(95% CI 90.2–94.0%),特异性为98.1%(95% CI 97.6–98.7%)。
- 各疾病特异性生物标志物检测的敏感性范围为68.7–100%,特异性范围为95.6–100%。
- 10重免疫检测与参考检测的总体一致率为96.7%(95% CI 96.7–97.3%),kappa值为0.91(95% CI 0.90–0.93)。
- 各病原体的kappa值范围为0.69–1.00。
临床怎么用
- 该检测可用小样本量在高通量格式下同时检测多种抗原的抗体,有望替代昂贵且高度专业化的单项检测以简化疾病监测。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Diagnostic assays that can simultaneously determine the presence of infection with multiple pathogens are key for diagnosis and surveillance. Current multiplex diagnostic assays are complex and often have limited availability. We developed a simple, multianalyte, pathogen detection assay for screening and serosurveillance using the Luminex Magpix platform that is high throughput and can be helpful in monitoring multiple diseases. The Luminex bead-based 10-plex immunoassay for the detection of HIV-1, HIV-2, Treponema pallidum, hepatitis B virus (HBV), hepatitis C virus (HCV), herpes simplex virus 1 (HSV-1), and HSV-2 infections was accomplished by coupling beads with specific antigens to detect IgG antibodies in plasma or serum samples. Each coupled antigen was systematically optimized, and the performance was evaluated using a panel of well-characterized specimens (n = 417) that contained antibodies to HIV-1, HIV-2, T. pallidum, HBV, HCV, HSV-1, and HSV-2. The multiplex assay had a sensitivity of 92.2% (95% Clopper-Pearson confidence interval [CI], 90.2 to 94.0%) and a specificity of 98.1% (95% CI, 97.6 to 98.7%). The sensitivities and specificities for disease-specific biomarker detection ranged from 68.7 to 100% and 95.6 to 100%, respectively. The results showed that the 10-plex immunoassay had an overall agreement of 96.7% (95% CI, 96.7 to 97.3%) with reference tests and a corresponding kappa value of 0.91 (95% CI, 0.90 to 0.93). Kappa values for the individual pathogens ranged from 0.69 to 1.00. The assay is robust and allows the simultaneous detection of antibodies to multiple antigens using a small sample volume in a high-throughput format. This assay has the potential to simplify disease surveillance by providing an alternative to expensive and highly specialized individual tests.
引用
- Yufenyuy EL, Vedapuri S, Zheng A, et al. Development of a Bead-Based Multiplex Assay for Use in Multianalyte Screening and Surveillance of HIV, Viral Hepatitis, Syphilis, and Herpes. J Clin Microbiol. 2022. PMID: 35387497. doi:10.1128/jcm.02348-21
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。