文献速递临床生化临床血液与体液质量管理与危急值

临床化学与血液学分析物的年度生物学变异及个性化参考区间

Annual biological variation and personalized reference intervals of clinical chemistry and hematology analytes.
PubMed 文献 · Clin Chem Lab Med · 2021-11-15

研究纳入43名连续六年每年体检的健康个体,计算24项临床化学与血液学分析物的年度生物学变异(BV)及衍生参数,并与每周数据比较。结果显示11项分析物的年度个体内BV显著高于每周数据,约50%分析物的个体性指数(II)<0.6,基于长期BV的个性化参考区间(RIper)对年度健康评估有重要价值。

要点

  • 年度个体内BV较每周数据更高,11项分析物差异显著。
  • 约50%分析物II<0.6,群体参考区间效用有限。
  • 基于长期BV的RIper有助于年度体检的个性化诊断。

核心结论

  • 对于年度健康体检人群,年度BV及相关参数可比每周BV更准确地评估实验室结果。
  • 基于长期BV数据的RIper对年度健康评估的个性化诊断非常有价值。

研究设计与样本

  • 纳入43名连续六年每年接受一次常规健康检查的健康个体,通过体格检查、心电图、超声和实验室检查筛选。
  • 计算年度BV数据及衍生参数如参考变化值(RCV)和个体性指数(II),并与每周数据比较。
  • 利用年度BV和稳态调定点计算个性化参考区间(RIper),并与群体参考区间(RIpop)比较。

主要发现

  • 建立了24项常用临床化学和血液学分析物的年度个体内BV(CVI)、RCV、II和RIper。
  • 在18项可比分析物中,11项的年度CVI估计值显著高于每周数据。
  • 约50%分析物的II<0.6,其RIpop的效用有限。
  • 大多数分析物的RIper分布范围仅覆盖RIpop的一小部分,8项分析物的参考范围指数<0.5。

临床怎么用

  • 在年度健康体检中,可考虑使用年度BV数据及RIper进行更个性化的结果评估。
  • 对于II<0.6的分析物,群体参考区间的效用有限,建议结合个体基线进行解读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: A large number of people undergo annual health checkup but accurate laboratory criterion for evaluating their health status is limited. The present study determined annual biological variation (BV) and derived parameters of common laboratory analytes in order to accurately evaluate the test results of the annual healthcare population. METHODS: A total of 43 healthy individuals who had regular healthcare once a year for six consecutive years, were enrolled using physical, electrocardiogram, ultrasonography and laboratory. The annual BV data and derived parameters, such as reference change value (RCV) and index of individuality (II) were calculated and compared with weekly data. We used annual BV and homeostatic set point to calculate personalized reference intervals (RIper) which were compared with population-based reference intervals (RIpop). RESULTS: We have established the annual within-subject BV (CVI), RCV, II, RIper of 24 commonly used clinical chemistry and hematology analytes for healthy individuals. Among the 18 comparable measurands, CVI estimates of annual data for 11 measurands were significantly higher than the weekly data. Approximately 50% measurands of II were <0.6, the utility of their RIpop were limited. The distribution range of RIper for most measurands only copied small part of RIpop with reference range index for 8 measurands <0.5. CONCLUSIONS: Compared with weekly BV, for annual healthcare individuals, annual BV and related parameters can provide more accurate evaluation of laboratory results. RIper based on long-term BV data is very valuable for "personalized" diagnosis on annual health assessments.

来源:Clin Chem Lab Med,查看原文。版权归原作者所有。

引用

  1. Wang S, Zhao M, Su Z, et al. Annual biological variation and personalized reference intervals of clinical chemistry and hematology analytes. Clin Chem Lab Med. 2021. PMID: 34773728. doi:10.1515/cclm-2021-0479

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。