文献速递医院感染防控细菌感染、耐药与抗菌药物

紫外线-C辅助消毒对免疫抑制患者耐药菌感染率的影响

Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms.
PubMed 文献 · Clin Infect Dis · 2022-01-01

在约翰霍普金斯医院4个肿瘤和1个实体器官移植病房开展整群随机交叉对照试验,评估每日及出院时在标准环境清洁基础上加用紫外线-C消毒对免疫抑制成人医疗保健相关耐万古霉素肠球菌和艰难梭菌感染率的影响。结论认为紫外线-C辅助消毒未降低上述感染率。

要点

  • 紫外线-C辅助消毒未降低艰难梭菌感染率(IRR 1.43,P=0.98)。
  • 标准环境清洁基础上加用紫外线-C未显示额外感染控制获益。

核心结论

  • 在肿瘤和实体器官移植病房,每日及出院时在标准环境清洁基础上加用紫外线-C消毒未降低VRE或艰难梭菌感染率。

研究设计与样本

  • 在约翰霍普金斯医院4个肿瘤和1个实体器官移植住院病房开展整群随机交叉对照试验,第1年各病房随机分配至紫外线-C加标准环境清洁或单纯标准环境清洁,经5周洗脱期后第2年交换分组。

临床怎么用

  • 在肿瘤和移植病房,不应常规期望通过加用紫外线-C消毒来降低VRE或艰难梭菌感染率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Our objective was to determine if the addition of ultraviolet-C (UV-C) light to daily and discharge patient room cleaning reduces healthcare-associated infection rates of vancomycin-resistant enterococci (VRE) and Clostridioides difficile in immunocompromised adults. METHODS: We performed a cluster randomized crossover control trial in 4 cancer and 1 solid organ transplant in-patient units at the Johns Hopkins Hospital, Baltimore, Maryland. For study year 1, each unit was randomized to intervention of UV-C light plus standard environmental cleaning or control of standard environmental cleaning, followed by a 5-week washout period. In study year 2, units switched assignments. The outcomes were healthcare-associated rates of VRE or C. difficile. Statistical inference used a two-stage approach recommended for cluster-randomized trials with <15 clusters/arm. RESULTS: In total, 302 new VRE infections were observed during 45787 at risk patient-days. The incidence in control and intervention groups was 6.68 and 6.52 per 1000 patient-days respectively; the unadjusted incidence rate ratio (IRR) was 0.98 (95% confidence interval [CI], .78 - 1.22; P = .54). There were 84 new C. difficile infections observed during 26118 at risk patient-days. The incidence in control and intervention periods was 2.64 and 3.78 per 1000 patient-days respectively; the unadjusted IRR was 1.43 (95% CI, .93 - 2.21; P = .98). CONCLUSIONS: When used daily and at post discharge in addition to standard environmental cleaning, UV-C disinfection did not reduce VRE or C. difficile infection rates in cancer and solid organ transplant units.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Rock C, Hsu YJ, Curless MS, et al. Ultraviolet-C Light Evaluation as Adjunct Disinfection to Remove Multidrug-Resistant Organisms. Clin Infect Dis. 2022. PMID: 34636853. doi:10.1093/cid/ciab896

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。