呼吸微生物组破坏与呼吸机相关下呼吸道感染风险
该研究纳入83例长期依赖机械通气的住院患者,纵向采集1066份下呼吸道标本,用16S rRNA测序和定量PCR分析微生物组。结果显示横断面微生物组破坏指数与VA-LRTI风险关联的 credible interval 较宽,而持续低Shannon多样性(<2.0)与VA-LRTI风险更稳健相关(OR 1.36,95%CI 1.10-1.72)。
要点
- 持续低Shannon多样性(<2.0)与VA-LRTI风险独立相关,OR 1.36(95%CI 1.10-1.72)。
- 横断面微生物组破坏指数在长期机械通气中区分VA-LRTI风险能力有限。
- 持续微生物组破坏或可识别高风险患者,指导感染预防干预。
核心结论
- 持续下呼吸道微生物组破坏(以连续低Shannon多样性为特征)与VA-LRTI风险稳健相关。
- 横断面微生物组破坏指数在长期机械通气期间区分VA-LRTI风险的能力有限。
研究设计与样本
- 前瞻性队列研究,纳入83例因长期依赖机械通气入住长期急性护理医院的患者。
- 纵向密集采样下呼吸道,共采集1066份标本,用16S rRNA测序和定量PCR分析微生物组。
主要发现
- 横断面MDIs(低Shannon多样性、高总细菌丰度)与VA-LRTI风险相关,但 posterior credible intervals 较宽。
- 持续低Shannon多样性(<2.0)每增加一天,VA-LRTI的OR为1.36(95%CI 1.10-1.72)。
- 该关联在多种VA-LRTI临床定义下一致。
关键数值与推荐
- 持续低Shannon多样性定义为连续天数Shannon多样性<2.0。
- VA-LRTI风险关联的OR为1.36(95%CI 1.10-1.72),对应每增加一天低Shannon多样性。
临床怎么用
- 对长期机械通气患者,可动态监测下呼吸道Shannon多样性以识别VA-LRTI高风险人群。
- 持续低Shannon多样性或可作为感染预防干预的靶向指标。
局限性
- 样本量83例,横断面关联的 posterior credible intervals 较宽,统计精度有限。
- 研究人群为长期急性护理医院内长期机械通气患者,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Ventilator-associated lower respiratory tract infection (VA-LRTI) is common among critically ill patients and has been associated with increased morbidity and mortality. In acute critical illness, respiratory microbiome disruption indices (MDIs) have been shown to predict risk for VA-LRTI, but their utility beyond the first days of critical illness is unknown. We sought to characterize how MDIs previously shown to predict VA-LRTI at initiation of mechanical ventilation change with prolonged mechanical ventilation, and if they remain associated with VA-LRTI risk. METHODS: We developed a cohort of 83 subjects admitted to a long-term acute care hospital due to their prolonged dependence on mechanical ventilation; performed dense, longitudinal sampling of the lower respiratory tract, collecting 1066 specimens; and characterized the lower respiratory microbiome by 16S rRNA sequencing as well as total bacterial abundance by 16S rRNA quantitative polymerase chain reaction. RESULTS: Cross-sectional MDIs, including low Shannon diversity and high total bacterial abundance, were associated with risk for VA-LRTI, but associations had wide posterior credible intervals. Persistent lower respiratory microbiome disruption showed a more robust association with VA-LRTI risk, with each day of (base e) Shannon diversity <2.0 associated with a VA-LRTI odds ratio of 1.36 (95% credible interval, 1.10-1.72). The observed association was consistent across multiple clinical definitions of VA-LRTI. CONCLUSIONS: Cross-sectional MDIs have limited ability to discriminate VA-LRTI risk during prolonged mechanical ventilation, but persistent lower respiratory tract microbiome disruption, best characterized by consecutive days with low Shannon diversity, may identify a population at high risk for infection and may help target infection-prevention interventions.
引用
- Harrigan JJ, Abdallah HO, Clarke EL, et al. Respiratory Microbiome Disruption and Risk for Ventilator-Associated Lower Respiratory Tract Infection. Clin Infect Dis. 2022. PMID: 34363467. doi:10.1093/cid/ciab678
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。