文献速递结核与非结核分枝杆菌医院感染防控

混合痰标本Xpert MTB/RIF检测在COVID-19大流行期间的系统综述

Systematic Review of Pooling Sputum as an Efficient Method for Xpert MTB/RIF Tuberculosis Testing during the COVID-19 Pandemic.
PubMed 文献 · Emerg Infect Dis · 2021-01-01

该系统综述检索文献评估混合痰标本GeneXpert检测(Xpert MTB/RIF或Ultra)能否达到与单样本检测相似的敏感性和特异性。从6篇文献发现,2样本混合的敏感性为87.5%和96.0%(平均94%,95%CI 89.0%-98.0%),4样本混合平均敏感性91%(Xpert MTB/RIF)和98%(Ultra),混合>4样本敏感性降低;两项研究报告特异性99%-100%,节省试剂盒27%-31%。结果表明混合检测可提高GeneXpert检测效率。

要点

  • 2样本混合Xpert MTB/RIF平均敏感性94%(95%CI 89.0%-98.0%)。
  • 4样本混合敏感性:Xpert MTB/RIF平均91%,Ultra平均98%。
  • 混合检测特异性99%-100%,可节省试剂盒27%-31%。

核心结论

  • 混合痰标本进行GeneXpert检测可能提高结核病检测效率,尤其在试剂盒和人员短缺时。

研究设计与样本

  • 系统综述,检索文献评估混合痰标本与单样本GeneXpert检测的敏感性和特异性,共纳入6篇文献。

主要发现

  • 2样本混合Xpert MTB/RIF的敏感性为87.5%和96.0%(2项研究),平均94%(95%CI 89.0%-98.0%)。
  • 4样本混合Xpert MTB/RIF平均敏感性91%(2项研究),Ultra平均98%(2项研究)。
  • 混合>4样本敏感性降低。
  • 两项研究报告混合检测特异性达99%-100%,并节省试剂盒27%-31%。

关键数值与推荐

  • 2样本混合Xpert MTB/RIF平均敏感性94%(95%CI 89.0%-98.0%)。
  • 4样本混合Xpert MTB/RIF平均敏感性91%,Ultra平均98%。
  • 混合检测特异性99%-100%,试剂盒节省27%-31%。

临床怎么用

  • 在试剂盒或人员短缺时,可考虑混合痰标本进行GeneXpert检测以提高效率。
  • 混合样本数不宜超过4个,以避免敏感性下降。

局限性

  • 纳入研究数量有限(共6篇),部分分析仅基于2项研究。
  • 未报告混合检测对治疗启动时间等临床结局的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

GeneXpert-based testing with Xpert MTB/RIF or Ultra assays is essential for tuberculosis diagnosis. However, testing may be affected by cartridge and staff shortages. More efficient testing strategies could help, especially during the coronavirus disease pandemic. We searched the literature to systematically review whether GeneXpert-based testing of pooled sputum samples achieves sensitivity and specificity similar to testing individual samples; this method could potentially save time and preserve the limited supply of cartridges. From 6 publications, we found 2-sample pools using Xpert MTB/RIF had 87.5% and 96.0% sensitivity (average sensitivity 94%; 95% CI 89.0%-98.0%) (2 studies). Four-sample pools averaged 91% sensitivity with Xpert MTB/RIF (2 studies) and 98% with Ultra (2 studies); combining >4 samples resulted in lower sensitivity. Two studies reported that pooling achieved 99%-100% specificity and 27%-31% in cartridge savings. Our results show that pooling may improve efficiency of GeneXpert-based testing.

来源:Emerg Infect Dis,查看原文。版权归原作者所有。

引用

  1. Cuevas LE, Santos VS, Lima SVMA, et al. Systematic Review of Pooling Sputum as an Efficient Method for Xpert MTB/RIF Tuberculosis Testing during the COVID-19 Pandemic. Emerg Infect Dis. 2021. PMID: 33622482. doi:10.3201/eid2703.204090

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。