文献速递医院感染防控细菌感染、耐药与抗菌药物

六家急性照护机构接触预防与非接触预防患者房间的环境污染

Environmental Contamination of Contact Precaution and Non-Contact Precaution Patient Rooms in Six Acute Care Facilities.
PubMed 文献 · Clin Infect Dis · 2021-01-01

该研究在6家急性照护医院的对MDRO接触预防(CP)与非CP房间、护士站及移动设备表面采样,发现CP房间MDRO污染率(32%)高于非CP房间(12%),但非CP房间污染并不少见,可能为MDRO持续传播的重要储源。

要点

  • CP房间表面MDRO污染率高于非CP房间(32% vs 12%)。
  • 非CP房间表面MDRO污染并不少见,可能提示无症状携带或清洁不足。
  • CP与非CP房间及MDRO阳性与阴性房间的表面总生物负载无显著差异。

核心结论

  • CP房间表面比非CP房间表面更频繁被MDRO污染,但非CP房间污染并不少见,可能是MDRO持续传播的重要储源。

研究设计与样本

  • 在6家急性照护医院的内科、重症监护和移植病房,采用便利抽样对MDRO CP与非CP房间、护士站及移动设备表面采样,采样对清洁事件设盲。

主要发现

  • 估计13%的房间被至少1种MDRO污染。
  • CP房间209次房间-采样事件中32%检出MDRO,非CP房间234次中12%检出。
  • CP与非CP房间、MDRO阳性与阴性房间的表面生物负载无显著差异。

关键数值与推荐

  • CP房间定义为患者前6个月内临床或监测检测MRSA、VRE、CRE或不动杆菌阳性,或前30天内艰难梭菌毒素阳性;不符合者为非CP房间。

临床怎么用

  • 非CP房间表面MDRO污染并不少见,提示应关注非CP房间的清洁与手卫生,以减少潜在传播。

局限性

  • 采用便利抽样,采样对清洁事件设盲,可能影响结果代表性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Environmental contamination is an important source of hospital multidrug-resistant organism (MDRO) transmission. Factors such as patient MDRO contact precautions (CP) status, patient proximity to surfaces, and unit type likely influence MDRO contamination and bacterial bioburden levels on patient room surfaces. Identifying factors associated with environmental contamination in patient rooms and on shared unit surfaces could help identify important environmental MDRO transmission routes. METHODS: Surfaces were sampled from MDRO CP and non-CP rooms, nursing stations, and mobile equipment in acute care, intensive care, and transplant units within 6 acute care hospitals using a convenience sampling approach blinded to cleaning events. Precaution rooms had patients with clinical or surveillance tests positive for methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, carbapenem-resistant Enterobacteriaceae or Acinetobacter within the previous 6 months, or Clostridioides difficile toxin within the past 30 days. Rooms not meeting this definition were considered non-CP rooms. Samples were cultured for the above MDROs and total bioburden. RESULTS: Overall, an estimated 13% of rooms were contaminated with at least 1 MDRO. MDROs were detected more frequently in CP rooms (32% of 209 room-sample events) than non-CP rooms (12% of 234 room-sample events). Surface bioburden did not differ significantly between CP and non-CP rooms or MDRO-positive and MDRO-negative rooms. CONCLUSIONS: CP room surfaces are contaminated more frequently than non-CP room surfaces; however, contamination of non-CP room surfaces is not uncommon and may be an important reservoir for ongoing MDRO transmission. MDRO contamination of non-CP rooms may indicate asymptomatic patient MDRO carriage, inadequate terminal cleaning, or cross-contamination of room surfaces via healthcare personnel hands.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Tanner WD, Leecaster MK, Zhang Y, et al. Environmental Contamination of Contact Precaution and Non-Contact Precaution Patient Rooms in Six Acute Care Facilities. Clin Infect Dis. 2021. PMID: 33512527. doi:10.1093/cid/ciaa1602

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。