两种儿童隐孢子虫病诊断试验的性能与操作可行性:CRYPTO-POC前瞻性诊断准确性研究
该研究在埃塞俄比亚两家医疗机构前瞻性纳入5岁以下腹泻或痢疾儿童,评估LED-AP镜检和侧流试纸条检测隐孢子虫的准确性。以qIFAT、ELISA和qPCR复合标准为参照,LED-AP灵敏度88%、特异度99%,侧流试纸条灵敏度89%、特异度99%。两者均适用于低资源环境。
要点
- LED-AP镜检对儿童隐孢子虫病灵敏度88%、特异度99%。
- 侧流试纸条灵敏度89%、特异度99%,无需显微镜。
- 两者均可与现有实验室基础设施整合用于低资源环境。
核心结论
- LED-AP对儿童隐孢子虫病具有高灵敏度和特异度,可作为双重用途技术与现有实验室基础设施整合。
- 侧流试纸条具有相似的灵敏度和特异度,提供无需显微镜的替代方案,但购买成本未知且尚未上市。
研究设计与样本
- 前瞻性诊断准确性研究,在埃塞俄比亚两家医疗机构连续纳入5岁以下腹泻或痢疾儿童。
- 共检测912名腹泻或痢疾儿童和706名来自嵌套病例对照亚研究的对照的粪便样本。
- 以qIFAT、ELISA和qPCR组成的复合参考标准进行独立盲法比较。
主要发现
- LED-AP灵敏度88%(95%CI 79-94;66/75),特异度99%(98-99;717/726)。
- 侧流试纸条灵敏度89%(95%CI 79-94;63/71),特异度99%(97-99;626/635)。
关键数值与推荐
- LED-AP灵敏度88%(95%CI 79-94),特异度99%(95%CI 98-99)。
- 侧流试纸条灵敏度89%(95%CI 79-94),特异度99%(95%CI 97-99)。
临床怎么用
- 在低资源环境中,LED-AP可与现有结核检测实验室基础设施整合用于隐孢子虫检测。
- 侧流试纸条无需显微镜,可作为隐孢子虫检测的替代方案,但需考虑其尚未上市和成本未知。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cryptosporidiosis is a common cause of diarrhoea in young children (aged younger than 24 months) in low-resource settings but is currently challenging to diagnose. Light-emitting diode fluorescence microscopy with auramine-phenol staining (LED-AP), recommended for tuberculosis testing, can also detect Cryptosporidium species. A lateral-flow test not requiring refrigerator storage (by contrast with most immunochromatographic lateral-flow assays) has also recently been developed for Cryptosporidium spp detection. We aimed to evaluate the diagnostic accuracy and operational feasibility of LED-AP and the lateral-flow test strip for cryptosporidiosis in children. METHODS: We did a prospective diagnostic accuracy study in two health-care facilities in Ethiopia, in a consecutive series of children younger than 5 years of age with diarrhoea (three or more loose stools within the previous 24 h) or dysentery (at least one loose stool with stains of blood within the previous 24 h). Stool samples were tested for Cryptosporidium spp by LED-AP and the lateral-flow test strip; accuracy of each test was estimated by independent and blind comparison with a composite reference standard comprising quantitative immunofluorescent antibody test (qIFAT), ELISA, and quantitative PCR (qPCR). Quantitative cutoff values for diarrhoea-associated infection were established in an embedded case-control substudy, with cases of cryptosporidiosis coming from the 15 districts in and around Jimma and the eight districts surrounding Serbo, and community controls without diarrhoea in the previous 48 h recruited by weekly frequency matching by geographical district of the household, age group, and enrolment week. FINDINGS: Stool samples from 912 children with diarrhoea or dysentery and 706 controls from the case-control substudy were tested between Dec 22, 2016, and July 6, 2018. Estimated reference-standard cutoff values for cryptosporidiosis positivity were 2·3 × 105 DNA copies per g of wet stool for qPCR, and 725 oocysts per g for qIFAT. LED-AP had a sensitivity for cryptosporidiosis of 88% (95% CI 79-94; 66 of 75 samples) and a specificity of 99% (98-99; 717 of 726 samples); the lateral-flow test strip had a sensitivity of 89% (79-94; 63 of 71 samples) and a specificity of 99% (97-99; 626 of 635 samples). INTERPRETATION: LED-AP has high sensitivity and specificity for cryptosporidiosis and should be considered as a dual-use technology that can be easily integrated with existing laboratory infrastructures in low-resource settings. The lateral-flow test strip has similar sensitivity and specificity and provides an alternative that does not require microscopy, although purchase cost of the test strip is unknown as it is not yet available on the market. FUNDING: Norwegian Research Council GLOBVAC fund, The Bill & Melinda Gates Foundation, Norwegian Society for Medical Microbiology, University of Bergen, and Vestfold Hospital Trust.
引用
- Johansen ØH, Abdissa A, Zangenberg M, et al. Performance and operational feasibility of two diagnostic tests for cryptosporidiosis in children (CRYPTO-POC): a clinical, prospective, diagnostic accuracy study. Lancet Infect Dis. 2020. PMID: 33278916. doi:10.1016/S1473-3099(20)30556-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。