CAP检测HIV相关NAFLD的最佳阈值:以MRI为参考标准
CAP的AUC为0.82(0.69-0.95),最佳切点为285 dB/m,阳性预测值93.2%,灵敏度73%,特异度78.6%。
要点
- CAP诊断HIV相关NAFLD的最佳切点为285 dB/m。
- CAP≥285 dB/m的阳性预测值为93.2%,灵敏度73%,特异度78.6%。
- 该切点与原发性NAFLD既往报道的切点相似,可纳入常规筛查。
核心结论
- CAP检测HIV相关NAFLD的最佳切点为285 dB/m,AUC为0.82(0.69-0.95)。
- CAP≥285 dB/m的阳性预测值为93.2%,灵敏度73%,特异度78.6%。
- 该切点与既往原发性NAFLD的切点相似,可纳入常规诊疗以识别HIV相关NAFLD风险患者。
研究设计与样本
- 纳入同时接受MRI-PDFF和CAP评估的患者,排除病毒性肝炎和过量饮酒等其他肝病。
- 采用ROC曲线分析确定CAP检测HIV相关NAFLD(肝脂肪≥5%)的最佳阈值。
主要发现
- 研究人群平均年龄48.6(±10.2)岁,平均BMI 30(±5.3)kg/m2。
- HIV相关NAFLD(MRI-PDFF≥5%)的患病率为80%。
- M探头和XL探头分别用于56%和44%的患者。
- CAP检测MRI-PDFF≥5%的AUC为0.82(0.69-0.95),切点为285 dB/m。
- CAP≥285 dB/m的阳性预测值为93.2%,灵敏度73%,特异度78.6%。
关键数值与推荐
- CAP检测HIV相关NAFLD(MRI-PDFF≥5%)的最佳切点为285 dB/m。
- CAP≥285 dB/m的阳性预测值为93.2%,灵敏度73%,特异度78.6%。
临床怎么用
- 可将CAP的285 dB/m切点纳入常规诊疗,用于识别HIV相关NAFLD风险患者。
- CAP作为超声即时检测方法,可用于HIV感染者肝脂肪变的筛查。
局限性
- NAFLD患病率高达80%,可能影响阳性预测值的普遍适用性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Controlled attenuation parameter (CAP) is an ultrasound-based point-of-care method to quantify liver fat; however, the optimal threshold for CAP to detect pathologic liver fat among persons living with human immunodeficiency virus (HIV; PLWH) is unknown. Therefore, we aimed to identify the diagnostic accuracy and optimal threshold of CAP for the detection of liver-fat among PLWH with magnetic resonance imaging proton-density fat fraction (MRI-PDFF) as the reference standard. METHODS: Patients from a prospective single-center cohort of PLWH at risk for HIV-associated nonalcoholic fatty liver disease (NAFLD) who underwent contemporaneous MRI-PDFF and CAP assessment were included. Subjects with other forms of liver disease including viral hepatitis and excessive alcohol intake were excluded. Receiver operatic characteristic (ROC) curve analysis were performed to identify the optimal threshold for the detection of HIV-associated NAFLD (liver fat ≥ 5%). RESULTS: Seventy PLWH (90% men) at risk for NAFLD were included. The mean (± standard deviation) age and body mass index were 48.6 (±10.2) years and 30 (± 5.3) kg/m2, respectively. The prevalence of HIV-associated NAFLD (MRI-PDFF ≥ 5%) was 80%. The M and XL probes were used for 56% and 44% of patients, respectively. The area under the ROC curve of CAP for the detection of MRI-PDFF ≥ 5% was 0.82 (0.69-0.95) at the cut-point of 285 dB/m. The positive predictive value of CAP ≥ 285 dB/m was 93.2% in this cohort with sensitivity of 73% and specificity of 78.6%. CONCLUSIONS: The optimal cut-point of CAP to correctly identify HIV-associated NAFLD was 285 dB/m, is similar to previously published cut-point for primary NAFLD and may be incorporated into routine care to identify patients at risk of HIV-associated NAFLD.
引用
- Ajmera VH, Cachay ER, Ramers CB, et al. Optimal Threshold of Controlled Attenuation Parameter for Detection of HIV-Associated NAFLD With Magnetic Resonance Imaging as the Reference Standard. Clin Infect Dis. 2021. PMID: 32975278. doi:10.1093/cid/ciaa429
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。