四种商业化实时PCR试剂盒检测衣原体阳性肛门直肠样本中性病淋巴肉芽肿的性能评估
该研究评估了四种商业化实时PCR试剂盒检测肛门直肠样本中性病淋巴肉芽肿(LGV)的性能,以法国国家细菌性性传播感染参考中心的方法为参考。共测试215份CT阳性肛门直肠标本(66例LGV,149例非LGV),总体一致性91.3%-100%,Kappa指数>0.8,临床灵敏度和特异度分别介于91%-100%和97%-100%。四种试剂盒均表现出很好的检测性能。
要点
- 四种商业化实时PCR试剂盒检测肛门直肠LGV总体一致性高(91.3%-100%),Kappa指数>0.8。
- 临床灵敏度91%-100%,特异度97%-100%,各试剂盒间存在一定差异。
- LGV鉴定具有治疗意义,LGV需多西环素治疗3周,非L型感染仅需1周。
核心结论
- 四种商业化实时PCR试剂盒在肛门直肠标本中检测LGV均表现出很好的性能。
研究设计与样本
- 研究纳入2017年连续收集的215份法国CT阳性肛门直肠标本,其中66份为LGV,149份为非LGV。
- 标本包括92份来自有症状的男男性行为者(MSM)和123份来自使用暴露前预防的无症状MSM。
- 评估四种商业化试剂盒:RealCycler CHSL(单重,全部标本检测)及RealCycler Universal ULCGEN、Allplex Genital Ulcer Assay、VIASURE Haemophilus ducreyi + CT LGV(三重,仅92份有症状MSM标本检测)。
- 以靶向pmpH的实验室自建实时PCR和ompA基因测序为参考方法。
主要发现
- 总体一致性范围为91.3%-100%(95%CI 83.7-100%),Kappa指数>0.8。
- 临床灵敏度范围为91%-100%(95%CI 80.8-100%),特异度范围为97%-100%(95%CI 87.1-100%)。
- 部分试剂盒表现优于其他试剂盒。
临床怎么用
- 这些商业化实时PCR试剂盒可用于肛门直肠标本中LGV的检测,性能与参考方法高度一致。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Lymphogranuloma venereum (LGV) is a sexually transmitted infection (STI) caused by Chlamydia trachomatis (CT) genovars L. The identification of LGV is of therapeutic interest because treatment requires 3 weeks of doxycycline compared with 1 week for infection with a non-L strain. The aim of this study was to evaluate the performance of four commercial real-time PCR kits in comparison with the reference methods used for LGV diagnosis by the French National Reference Centre (NRC) for bacterial STIs. METHODS: A total of 215 French CT-positive anorectal specimens collected consecutively in 2017 were used (66 LGV and 149 non-LGV). Among these, 92 were collected from symptomatic men who have sex with men (MSM) and 123 from asymptomatic MSM using pre-exposure prophylaxis. Four commercial assays were evaluated; a single-plex assay RealCycler CHSL kit (Progenie Molecular), tested on all the specimens, and three multiplex kits, the RealCycler Universal ULCGEN (Progenie Molecular), the Allplex Genital Ulcer Assay (Seegene) and the VIASURE Haemophilus ducreyi + CT LGV Real Time PCR Detection kit (CerTest Biotec), tested on the 92 samples from symptomatic MSM. Clinical performance was determined in comparison to the in-house real time PCR targeting the pmpH and the ompA gene sequencing. RESULTS: Overall agreement ranged between 91.3% and 100% (95% CI 83.7-100%) with very good Kappa index values (>0.8). The clinical sensitivities and specificities varied between 91% and 100% (95% CI 80.8-100%), and 97% and 100% (95% CI 87.1-100%), respectively, with some kits performing better than others. DISCUSSION: The four assays showed very good performance for the detection of LGV on anorectal specimens.
引用
- Touati A, Laurier-Nadalié C, Bébéar C, et al. Evaluation of four commercial real-time PCR assays for the detection of lymphogranuloma venereum in Chlamydia trachomatis-positive anorectal samples. Clin Microbiol Infect. 2020. PMID: 32771642. doi:10.1016/j.cmi.2020.07.040
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。