TBDetect痰涂片显微镜试剂盒多中心验证:提升结核分枝杆菌检出
在印度六中心对2086例疑似肺结核患者痰标本评估TBDetect试剂盒(BioFM滤膜浓缩)对比LED荧光显微镜和Ziehl-Neelsen涂片,以MGIT培养为参考标准。TBDetect总阳性率20%显著高于LED-FM的16.1%和ZN的16%(p<0.001),总体敏感性约55% vs 52%(p=0.14)和50.9%(p<0.05)。生物安全评估显示99.95%样本培养42天无菌,操作简便安全。
要点
- TBDetect痰浓缩涂片阳性率20%,显著高于LED-FM和ZN涂片。
- 以MGIT培养为参考,TBDetect敏感性约55%,高于ZN涂片但未显著优于LED-FM。
- TBDetect具生物安全性,99.95%样本培养42天无菌,操作简便。
核心结论
- TBDetect通过滤膜浓缩痰标本提升涂片阳性率和敏感性,且具生物安全性与操作便利性。
- 无需设备的TBDetect技术有望依托现有 microscopy 网络改善基层结核诊断。
研究设计与样本
- 六中心多中心验证研究,纳入2086例疑似肺结核患者痰标本。
- 以MGIT培养为参考标准(培养阳性367例),对比TBDetect、LED-FM和ZN涂片。
主要发现
- TBDetect总阳性率20%(417/2086),LED-FM为16.1%(337/2086),ZN为16%(333/2086),差异显著(p<0.001)。
- TBDetect总体敏感性约55%(202/367,95%CI 50–60%),LED-FM为52%(191/367,95%CI 47–57%,p=0.14),ZN为50.9%(187/367,95%CI 46–56%,p<0.05)。
- 六中心生物安全评估中99.95%样本(1873/1874)培养42天无菌。
临床怎么用
- 在基层实验室可利用现有 designated microscopy centres 和初级卫生中心网络开展TBDetect痰浓缩涂片。
- TBDetect操作简便且具生物安全性,适合资源有限环境提升涂片检出。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The present study aimed to evaluate the performance of the 'TBDetect' kit-based bio-safe fluorescent microscopy filter (BioFM-Filter) microscopy in comparison with direct smear microscopy and culture for the detection of pulmonary tuberculosis (TB) in a multi-centric setting in India. METHODS: The TBDetect kit enables sputum concentration through filtration using the BioFM-Filter for improved and bio-safe smear microscopy. We evaluated the performance of the TBDetect kit in a six-site multi-centric validation study on sputum collected from 2086 presumptive TB patients. RESULTS: The combined positivity of TBDetect microscopy performed on these sputum samples was 20% (n = 417/2086) vs 16.1% of light-emitting diode fluorescence microscopy (LED-FM, n = 337/2086) and 16% of Ziehl Neelsen (ZN) smear microscopy (n = 333/2086). The increment in positivity of TBDetect over both LED-FM and ZN smears was significant (p < 0.001). The overall sensitivity of TBDetect for six sites was ~55% (202/367, 95% confidence interval (CI): 50, 60%) vs 52% (191/367, 95% CI: 47, 57%) for LED-FM (p 0.14) and 50.9% (187/367, 95% CI: 46, 56%) for ZN smear (p < 0.05), using Mycobacterium Growth Indicator Tube culture (MGIT, n = 1949, culture positive, n = 367) as the reference standard. A bio-safety evaluation at six sites confirmed efficient sputum disinfection by TBDetect; 99.95% samples (1873/1874) were sterile after 42 days of incubation. Scientists and technicians at the study sites indicated the ease of use and convenience of TBDetect microscopy during feedback. CONCLUSIONS: TBDetect added value to the smear microscopy test due to its improved performance, convenience and user safety. These findings indicate that equipment-free TBDetect technology has the potential to improve TB diagnosis in basic laboratory settings by leveraging on the existing nationwide network of designated microscopy centres and primary healthcare centres.
引用
- Anthwal D, Gupta RK, Gomathi NS, et al. Evaluation of 'TBDetect' sputum microscopy kit for improved detection of Mycobacterium tuberculosis: a multi-centric validation study. Clin Microbiol Infect. 2020. PMID: 32835794. doi:10.1016/j.cmi.2020.08.020
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。