文献速递结核与非结核分枝杆菌

基于脂质指纹的MALDI-ToF用于分枝杆菌感染诊断的性能评估

Performance of lipid fingerprint-based MALDI-ToF for the diagnosis of mycobacterial infections.
PubMed 文献 · Clin Microbiol Infect · 2020-08-27

该研究评估了一种无需样本制备、基于完整细菌物种特异性脂质谱的MALDI-ToF MS方法,用于分枝杆菌鉴定。对273株分枝杆菌(含结核复合群和非结核分枝杆菌)的盲法测试显示,96.7%的结核复合群菌株和91.7%的非结核分枝杆菌物种被正确鉴定,方法快速(<10分钟)且高灵敏(所需细菌<1000)。结论认为完整细菌脂质谱分析为快速准确的分枝杆菌鉴定提供了生物安全的途径。

要点

  • 基于完整细菌脂质谱的MALDI-ToF MS可在<10分钟内鉴定分枝杆菌,所需细菌<1000。
  • 盲法测试中96.7%(204/211)结核复合群菌株和91.7%(22/24)非结核分枝杆菌物种被正确鉴定。
  • 该方法无需样本制备,使用热灭活细菌,降低生物安全风险。

核心结论

  • 完整细菌脂质谱分析为快速准确的分枝杆菌鉴定提供了生物安全的新途径。

研究设计与样本

  • 研究评估了基于完整细菌物种特异性脂质谱的MALDI-ToF MS方法,使用热灭活分枝杆菌直接点靶,无需样本制备。
  • 盲法研究纳入273株分枝杆菌菌株,包括结核复合群和非结核分枝杆菌,在Middlebrook 7H9培养基(含10% OADC)中37°C培养至2周。

主要发现

  • 方法快速(<10分钟)且高灵敏(所需细菌<1000)。
  • 96.7%(204/211)的结核复合群菌株被正确鉴定为结核复合群。
  • 91.7%(22/24)的非结核分枝杆菌物种被正确鉴定。

临床怎么用

  • 该脂质指纹MALDI-ToF方法可用于分枝杆菌的快速鉴定,无需复杂样本制备,且生物安全性较好。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Bacterial diagnosis of mycobacteria is often challenging because of the variability of the sensitivity and specificity of the assay used, and it can be expensive to perform accurately. Although matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has become the workhorse of clinical laboratories, the current MALDI methodology (which is based on cytosolic protein profiling) for mycobacteria is still challenging due to the number of steps involved (up to seven) and potential biosafety concerns. Knowing that mycobacteria produce surface-exposed species-specific lipids, we here hypothesized that the detection of those molecules could offer a rapid, reproducible and robust method for mycobacterial identification. METHODS: We evaluated the performance of an alternative methodology based on characterized species-specific lipid profiling of intact bacteria, without any sample preparation, by MALDI MS; it uses MALDI-time-of-flight (ToF) MS combined with a specific matrix (super-2,5-dihydroxybenzoic acid solubilized in an apolar solvent system) to analyse lipids of intact heat-inactivated mycobacteria. Cultured mycobacteria are heat-inactivated and loaded directly onto the MALDI target followed by addition of the matrix. Acquisition of the data is done in both positive and negative ion modes. Blinded studies were performed using 273 mycobacterial strains comprising both the Mycobacterium tuberculosis (Mtb) complex and non-tuberculous mycobacteria (NTMs) subcultured in Middlebrook 7H9 media supplemented with 10% OADC (oleic acid/dextrose/catalase) growth supplement and incubated for up to 2 weeks at 37°C. RESULTS: The method we have developed is fast (<10 mins) and highly sensitive (<1000 bacteria required); 96.7% of the Mtb complex strains (204/211) were correctly assigned as MTB complex and 91.7% (22/24) NTM species were correctly assigned based only on intact bacteria species-specific lipid profiling by MALDI-ToF MS. CONCLUSIONS: Intact bacterial lipid profiling provides a biosafe and unique route for rapid and accurate mycobacterial identification.

来源:Clin Microbiol Infect,查看原文。版权归原作者所有。

引用

  1. Gonzalo X, Broda A, Drobniewski F, et al. Performance of lipid fingerprint-based MALDI-ToF for the diagnosis of mycobacterial infections. Clin Microbiol Infect. 2020. PMID: 32861860. doi:10.1016/j.cmi.2020.08.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。