文献速递细菌感染、耐药与抗菌药物医院感染防控

ICU内MRSA传播:患者、环境与医护人员的基因组分析

MRSA Transmission in Intensive Care Units: Genomic Analysis of Patients, Their Environments, and Healthcare Workers.
PubMed 文献 · Clin Infect Dis · 2021-01-01

该研究在4个成人ICU中纳入医护人员,对患者体表、病房高频接触表面及医护人员手、手套和防护装备采样,用全基因组测序比较分离株。结果显示MRSA USA300和USA100菌株在患者、环境和医护人员间频繁传播,测序识别出ICU内甚至ICU间的可能传播。

要点

  • MRSA USA300和USA100在患者、环境与医护人员间频繁传播。
  • 全基因组测序可识别ICU内及ICU间的可能传播簇。
  • 部分医护人员进病房前已携带MRSA,提示需关注带入传播。

核心结论

  • MRSA USA300和USA100菌株在患者、环境和医护人员间频繁传播,全基因组测序识别出ICU内甚至ICU间的可能传播。

研究设计与样本

  • 2015年9月至2016年2月 enrolled 4个成人ICU的医护人员,对患者体表、病房高频接触表面及医护人员手、手套和防护装备采样,用全基因组测序比较分离株。

主要发现

  • 共对66次患者接触的413株MRSA分离株测序,其中38%为USA300、52%为USA100。
  • 66名医护人员中有6名在进病房前已携带MRSA。
  • 单次患者接触的分离株通常为USA100或USA300,8次(12%)接触同时分离出USA300和USA100。
  • 全基因组测序显示患者、医护人员和环境分离株常遗传相似,但接触间存在显著多样性。
  • 发现5个USA100和1个USA300簇内含相似菌株(<22个单核苷酸变异,多数<10个),其中4簇来自同一ICU的接触,5簇发生在1周内。

临床怎么用

  • 应关注医护人员进病房前携带MRSA及防护装备污染在ICU传播中的作用。
  • 全基因组测序可用于识别ICU内及ICU间的MRSA传播簇,辅助感染防控。

局限性

  • 未来需结合详细接触追踪与基因组数据进一步阐明MRSA传播路径和干预点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Methicillin-resistant Staphylococcus aureus (MRSA)-and now USA300 MRSA-is a significant intensive care unit (ICU) pathogen; healthcare worker (HCW) contamination may lead to patient cross-transmission. METHODS: From September 2015 to February 2016, to study the spread of MRSA, we enrolled HCWs in 4 adult ICUs caring for patients on MRSA contact precautions. Samples were collected from patient body sites and high-touch surfaces in patient rooms. HCW hands, gloves, and personal protective equipment were sampled pre/post-patient encounter. Whole genome sequencing (WGS) was used to compare isolates from patients, HCWs, and environment. RESULTS: There were 413 MRSA isolates sequenced (38% USA300, 52% USA100) from 66 patient encounters. Six of 66 HCWs were contaminated with MRSA prior to room entry. Isolates from a single patient encounter were typically either USA100 or USA300; in 8 (12%) encounters both USA300 and USA100 were isolated. WGS demonstrated that isolates from patients, HCWs, and environment often were genetically similar, although there was substantial between-encounter diversity. Strikingly, there were 5 USA100 and 1 USA300 clusters that contained similar strains (<22 single-nucleotide variants [SNVs], with most <10 SNVs) within the cluster despite coming from different encounters, suggesting intra- and inter-ICU spread of strains, that is, 4 of these genomic clusters were from encounters in the same ICU; 5 of 6 clusters occurred within 1 week. CONCLUSIONS: We demonstrated frequent spread of MRSA USA300 and USA100 strains among patients, environment, and HCWs. WGS identified possible spread within and even between ICUs. Future analysis with detailed contact tracing in conjunction with genomic data may further elucidate pathways of MRSA spread and points for intervention.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Popovich KJ, Green SJ, Okamoto K, et al. MRSA Transmission in Intensive Care Units: Genomic Analysis of Patients, Their Environments, and Healthcare Workers. Clin Infect Dis. 2021. PMID: 32505135. doi:10.1093/cid/ciaa731

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。