HIV感染与心电图异常:CHART队列基线评估
这项横断面研究纳入中国台州1412例HIV阳性者和2824例年龄性别频数匹配的HIV阴性者,发现HIV阳性者窦性心动过速和ST/T波异常患病率更高,窦性心动过缓更低,调整传统危险因素后关联仍显著。HIV感染独立关联窦性心动过速和ST/T波异常,建议将心电图筛查纳入常规HIV照护。
要点
- HIV阳性者窦性心动过速和ST/T波异常患病率显著高于阴性者。
- 调整传统危险因素后,HIV感染仍独立关联上述心电图异常。
- 已知HIV感染病程较长者ST/T波异常风险更高。
核心结论
- HIV感染独立关联窦性心动过速和ST/T波异常,建议在中国将心电图筛查纳入常规HIV照护。
研究设计与样本
- 横断面评估,纳入1412例HIV阳性者和2824例HIV阴性者,年龄18至75岁,按年龄和性别频数匹配,源自2017年2月至12月中国台州CHART基线调查。
主要发现
- HIV阳性者窦性心动过速患病率为5.6%(79/1412),高于阴性者的1.3%(36/2824),p < 0.001。
- HIV阳性者ST/T波异常患病率为14.9%(211/1412),高于阴性者的9.4%(264/1412),p < 0.001。
- HIV阳性者窦性心动过缓患病率为4.8%(68/1412),低于阴性者的7.5%(211/2824),p 0.001。
- 调整传统危险因素后,窦性心动过速aOR 4.68(95%CI 3.06-7.17),ST/T波异常aOR 1.89(95%CI 1.54-2.34),窦性心动过缓aOR 0.60(95%CI 0.44-0.80)。
- 仅在HIV阳性者中,颈动脉内膜中层厚度0.78-1.00 mm与ST/T波异常相关(aOR 1.46,95%CI 1.01-2.12),>1.00 mm的aOR 2.18(95%CI 1.39-3.42)。
关键数值与推荐
- 仅在HIV阴性者中,高血压前期与窦性心动过速相关(aOR 5.61,95%CI 1.76-17.91),高血压的aOR 12.62(95%CI 3.60-44.27)。
- 仅在HIV阴性者中,高血压与ST/T波异常相关(aOR 2.04,95%CI 1.41-2.95)。
- 已知HIV感染病程较长是ST/T波异常的唯一HIV特异性因素(aOR 1.61,95%CI 1.17-2.22),窦性心动过速无HIV特异性因素。
临床怎么用
- 建议在中国将心电图筛查整合入常规HIV照护。
- 对HIV感染者应关注窦性心动过速和ST/T波异常,尤其已知感染病程较长者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate the prevalence of various electrocardiogram (ECG) abnormalities among HIV-positive and HIV-negative individuals. METHODS: This cross-sectional evaluation included 1412 HIV-positive and 2824 HIV-negative participants aged 18 to 75 years and frequency matched by age and sex, derived from the baseline survey of Comparative HIV and Aging Research in Taizhou (CHART), China, between February and December 2017. RESULTS: HIV-positive individuals had higher prevalence of sinus tachycardia (5.6% (79/1412) vs. 1.3% (36/2824), p < 0.001) and ST/T wave abnormalities (14.9% (211/1412) vs. 9.4% (264/1412), p < 0.001) but lower prevalence of sinus bradycardia (4.8% (68/1412) vs. 7.5% (211/2824), p 0.001); such associations remained statistically significant after adjusting for traditional risk factors (respectively, adjusted odds ratio (aOR) 4.68, 95% confidence interval (CI) 3.06-7.17; aOR 1.89, 95% CI 1.54-2.34; aOR 0.60, 95% CI 0.44-0.80). In adjusted models, being in higher carotid intima-media thickness categories was significantly associated with ST/T abnormalities in HIV-positive individuals only (0.78-1.00 mm: aOR 1.46, 95% CI 1.01-2.12; >1.00 mm: aOR 2.18, 95% CI 1.39-3.42), whereas being in higher blood pressure categories was significantly associated with both sinus tachycardia (prehypertension: aOR 5.61, 95% CI 1.76-17.91; hypertension: aOR 12.62, 95% CI 3.60-44.27) and ST/T abnormalities (hypertension: aOR 2.04, 95% CI 1.41-2.95) in HIV-negative individuals only. Longer duration of known HIV infection was the only HIV-specific factor of ST/T abnormalities (aOR 1.61, 95% CI 1.17-2.22), with none for sinus tachycardia. CONCLUSIONS: HIV infection is independently associated with sinus tachycardia and ST/T abnormalities. Further research is needed to investigate specific mechanisms by which HIV infection leads to ECG abnormalities and to evaluate whether inclusion of ECG parameters improves cardiovascular disease prediction. Integrating ECG screening into routine HIV care is recommended in China.
引用
- Ding Y, Zhu B, Lin H, et al. HIV infection and electrocardiogram abnormalities: baseline assessment from the CHART cohort. Clin Microbiol Infect. 2020. PMID: 32194160. doi:10.1016/j.cmi.2020.03.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。