该研究在澳大利亚观察性队列中评估Xpert HCV VL FS检测HCV RNA的时间。1468名参与者中1386例获有效结果,HCV RNA检出率23%(325/1386)。可检出者中位检出时间32分钟,80%(261/325)在≤40分钟内检出;不可检出者中位结果时间57分钟。中位检出时间取决于HCV RNA水平。

要点

  • Xpert HCV VL FS可在1小时内定量HCV RNA,支持同次就诊诊断与治疗。
  • 可检出HCV RNA者中位检出时间32分钟,80%在≤40分钟内检出。
  • 中位检出时间取决于HCV RNA水平,监测首次检出时间或可加速诊断。

核心结论

  • 通过监测Xpert HCV VL FS检测中HCV RNA首次检出的时间而非定量,可实现更快速的HCV诊断,但当前平台尚不支持此功能。

研究设计与样本

  • 研究为在澳大利亚开展的观察性队列,评估Xpert HCV VL FS检测HCV RNA的时间。
  • 2018年5月至2019年共纳入1468名参与者,1426例接受Xpert HCV VL FS检测,1386例获得有效结果。

主要发现

  • HCV RNA检出率为23%(325/1386)。
  • HCV RNA不可检出者(n=1061)中位结果时间为57分钟。
  • HCV RNA可检出者(n=325)中位HCV RNA检出时间为32分钟,80%(261/325)在≤40分钟内检出。
  • 中位HCV RNA检出时间取决于HCV RNA水平。

临床怎么用

  • Xpert HCV VL FS指尖采血即时检测可在1小时内定量HCV RNA,支持同次就诊诊断与治疗。
  • 监测HCV RNA首次检出时间而非定量可能缩短HCV诊断等待时间并改善治疗衔接,但需平台支持。

局限性

  • 当前平台不允许监测HCV RNA首次检出时间而非定量。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Xpert HCV Viral Load Fingerstick assay (Xpert HCV VL FS) is a point-of-care test quantifying HCV RNA in <1 hour, enabling same-visit diagnosis and treatment. METHODS: This study evaluated time to HCV RNA detection using the Xpert HCV VL FS assay. Fingerstick whole-blood samples were collected from participants in an observational cohort in Australia. RESULTS: In May 2018-2019, 1468 participants were enrolled, 1426 had Xpert HCV VL FS testing performed, and 1386 had a valid result. HCV RNA was detected in 23% (325/1386). Among people with undetectable HCV RNA (n = 1061), median time to result was 57 minutes. Among people with detectable HCV RNA (n = 325), median time to HCV RNA detection was 32 minutes and 80% (261/325) had a detectable HCV RNA result in ≤40 minutes. Median time to HCV RNA detection was dependent on HCV RNA level. CONCLUSIONS: A quicker HCV diagnosis could be achieved by monitoring the time when HCV RNA is first detected with the Xpert HCV VL FS test, rather than HCV RNA quantification, although the current platform does not allow for this. These findings could facilitate new strategies to reduce waiting times for an HCV diagnosis and improve linkage to treatment.