文献速递细菌感染、耐药与抗菌药物医院感染防控

BD Kiestra InoqulA 接种图案对 MRSA 与 CRE 监测样本菌落分离及周转时间的影响

Impact of BD Kiestra InoqulA streaking patterns on colony isolation and turnaround time of methicillin-resistant Staphylococcus aureus and carbapenem-resistant Enterobacterale surveillance samples.
PubMed 文献 · Clin Microbiol Infect · 2020-01-11

该研究评估在 BD Kiestra InoqulA 上采用不同接种图案对耐甲氧西林金黄色葡萄球菌(MRSA)和碳青霉烯耐药肠杆菌目(CRE)筛查样本菌落分离及周转时间(TAT)的影响。共分析 1571 份 MRSA 阳性筛查样本和 424 份 CRE 阳性筛查样本,比较标准图案与替代图案。结果显示替代图案使可供确认试验的分离菌落不足的平板数及 TAT 超过 36 小时的病例数均减少,并减少亚培养所需人力和材料。

要点

  • 替代接种图案可减少 MRSA 筛查平板分离菌落不足的情况。
  • 替代图案使 MRSA 与 CRE 筛查 TAT 超过 36 小时的病例减少。
  • 改变接种图案可减少亚培养混合菌落所需人力和材料。

核心结论

  • 在 BD Kiestra InoqulA 上改用替代接种图案,可使更多平板获得足够分离菌落,减少亚培养混合菌落所需人力和材料,并整体改善 TAT。

研究设计与样本

  • 研究共纳入 1571 份 MRSA 阳性筛查样本,其中 755 块平板采用标准图案(4-Quadrant uniform S200),816 块采用替代图案(Zigzag 3.5-1 S200)。
  • 研究共纳入 424 份 CRE 阳性筛查样本,其中 211 块平板采用标准图案(Zigzag 2.5-1 inoc S200),213 块采用替代定制图案(Zigzag 3.5-1 vertstreak s200)。

主要发现

  • MRSA 筛查中,分离菌落不足以进行确认试验的平板由标准图案的 75 块(9.9%)降至替代图案的 18 块(2.2%)。
  • MRSA 筛查中,TAT 超过 36 小时的病例由 144 例(19.1%)降至 20 例(2.4%)。
  • CRE 筛查中,分离菌落不足以进行当日确认试验的平板由标准图案的 16 块(7.6%)降至替代定制图案的 2 块(1.1%)。
  • CRE 筛查中,TAT 超过 36 小时的病例由 16 例(7.6%)降至 7 例(3.3%)。

临床怎么用

  • 在采用 BD Kiestra InoqulA 进行 MRSA 与 CRE 监测平板接种时,可考虑改用替代接种图案以改善菌落分离并缩短 TAT。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To determine if using alternative streaking patterns on the BD Kiestra InoqulA can impact colony isolation and improve turnaround time (TAT) of methicillin-resistant Staphylococcus aureus (MRSA) and carbapenem-resistant Enterobacterales (CRE) screening samples. METHODS: A total of 1571 positive MRSA screening samples were studied, of which 755 screening plates were streaked by the standard pattern (4-Quadrant uniform S200) and 816 plates were streaked by an alternative pattern (Zigzag 3.5-1 S200). A total of 424 CRE-positive screening samples were studied, of which 211 screening plates were streaked by the standard pattern (Zigzag 2.5-1 inoc S200) and 213 plates were streaked by an alternative customized pattern (Zigzag 3.5-1 vertstreak s200). RESULTS: There was a reduction in the number of MRSA screening plates with insufficient isolated colonies for confirmatory testing from 75 plates (9.9%) when using the standard pattern to 18 plates (2.2%) when using the alternative streaking pattern. MRSA cases with a TAT above 36 hours also reduced significantly from 144 (19.1%) to 20 (2.4%). The number of CRE screening plates with insufficient colonies for same-day confirmatory testing reduced from 16 (7.6%) when using the standard pattern to two plates (1.1%) when using the alternative customized pattern. CRE cases with a TAT above 36 hours also reduced from 16 (7.6%) to seven (3.3%). CONCLUSIONS: The change in streaking patterns resulted in more plates with sufficient isolated colonies as well as reduced man-hours and materials required to perform subculture of mixed colonies and overall improvements in TAT.

来源:Clin Microbiol Infect,查看原文。版权归原作者所有。

引用

  1. Cheng CWR, Ong CH, Chan DSG, et al. Impact of BD Kiestra InoqulA streaking patterns on colony isolation and turnaround time of methicillin-resistant Staphylococcus aureus and carbapenem-resistant Enterobacterale surveillance samples. Clin Microbiol Infect. 2020. PMID: 31935564. doi:10.1016/j.cmi.2020.01.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。