文献速递结核与非结核分枝杆菌

胸腔积液游离结核分枝杆菌DNA检测诊断结核性胸膜炎的准确性研究

Cell-free Mycobacterium tuberculosis DNA test in pleural effusion for tuberculous pleurisy: a diagnostic accuracy study.
PubMed 文献 · Clin Microbiol Infect · 2019-12-02

该研究前瞻性纳入286例疑似结核性胸膜炎成人,评估胸腔积液游离结核分枝杆菌DNA检测(cf-TB)的诊断效能,以复合参考标准判定。cf-TB对确诊结核性胸膜炎的敏感度为79.5%,显著高于Xpert(38.5%)和培养(27.1%),作者推荐cf-TB作为结核性胸膜炎的一线检测。

要点

  • cf-TB诊断结核性胸膜炎敏感度79.5%,显著优于Xpert和培养。
  • 以Xpert和/或培养为参考,cf-TB敏感度达96.6%。
  • 建议将cf-TB作为结核性胸膜炎的一线检测。

核心结论

  • cf-TB检测胸腔积液诊断结核性胸膜炎的敏感度明显优于Xpert和培养,推荐作为一线检测。

研究设计与样本

  • 前瞻性诊断准确性研究,连续纳入286例≥18岁疑似结核性胸膜炎成人,胸腔积液标本前瞻性收集。

主要发现

  • 122例符合复合参考标准确诊结核性胸膜炎,cf-TB敏感度79.5%(97/122,95%CI 72.4-86.7)。
  • cf-TB敏感度显著高于Xpert(38.5%,95%CI 29.9-47.2;47/122;p<0.001)和培养(27.1%,95%CI 19.2-34.9;33/122;p<0.001)。
  • 以胸腔积液Xpert和/或培养为参考标准,cf-TB敏感度96.6%(57/59,95%CI 92.0-100.0),显著高于Xpert(79.7%,95%CI 69.4-89.9;47/59;p=0.004)和培养(55.9%,95%CI 43.3-68.6;33/59;p<0.001)。

临床怎么用

  • 对疑似结核性胸膜炎患者,可优先采用胸腔积液cf-TB检测以提高诊断敏感度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Tuberculous pleurisy (TP) diagnosis remains difficult, with the sensitivity of Xpert MTB/RIF (Xpert) and mycobacterial culture (culture) only about 30-50%. We aimed to assess the diagnostic performance of a cell-free Mycobacterium tuberculosis DNA test (cf-TB) in pleural effusion for TP. METHODS: Adults (≥18 years) with suspected TP presenting with pleural effusion were consecutively recruited, and pleural effusion specimens were prospectively collected in Beijing Chest Hospital, Beijing, China. After centrifuging pleural effusion, sediments were used for culture, Xpert and T-SPOT.TB assay, whereas supernatants were used for cf-TB and adenosine deaminase assay. The diagnostic performance was assessed against a composite reference standard. RESULTS: From June 2015 to December 2018, we prospectively evaluated 286 adults with suspected TP. One hundred twenty-two participants were classified as definite TP based on the prespecified composite reference standard. The cf-TB produced a sensitivity of 79.5% (97/122, 95% confidence interval (CI) 72.4- 86.7) for definite TP, which was superior to Xpert (38.5% (29.9-47.2); 47/122; p < 0.001) and culture (27.1% (19.2-34.9); 33/122; p < 0.001). With pleural effusion Xpert and/or culture as the reference standard, cf-TB showed 96.6% (57/59, 95% CI 92.0-100.0) sensitivity, which was also significantly higher than Xpert (79.7%, 95% CI 69.4-89.9; 47/59; p 0.004) and culture (55.9%, 95% CI: 43.3-68.6; 33/59; p < 0.001). CONCLUSIONS: The cf-TB clearly showed improved sensitivity compared with Xpert and culture. We recommend cf-TB as the first-line test for TP diagnosis.

来源:Clin Microbiol Infect,查看原文。版权归原作者所有。

引用

  1. Yang X, Che N, Duan H, et al. Cell-free Mycobacterium tuberculosis DNA test in pleural effusion for tuberculous pleurisy: a diagnostic accuracy study. Clin Microbiol Infect. 2019. PMID: 31805377. doi:10.1016/j.cmi.2019.11.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。