抗生素浸渍脑室外引流管抗菌活性持久性的前瞻性研究
结果显示AI-EVD抗菌活性在体内快速下降,对MRSA和MRSE的抑制随置管时间和脑脊液引流量显著降低,且9%发生定植、4%发生感染。
要点
- AI-EVD抗菌活性在体内快速下降,对MRSA和MRSE的抑制随置管时间和引流量降低。
- 利福平浓度快速显著下降,与置管时间和脑脊液引流量相关。
- 9%发生引流管相关定植,4%发生感染,定植以葡萄球菌为主。
核心结论
- AI-EVD的抗菌活性在体内快速下降。
- 抗生素浸渍未能防止9%的病例发生敏感菌株定植。
研究设计与样本
- 拔管后对每根AI-EVD内外表面进行培养和抗菌活性评估,分别以MSSA、MRSA或MRSE单株挑战。
主要发现
- 发生5例(9%)脑室造口相关定植和2例(4%)脑室造口相关感染,定植主要菌为葡萄球菌(4/5)。
- 对MRSA和MRSE的抑制随置管时间(内外侧P<0.02)和脑脊液引流量(MRSE双侧P<0.005,MRSA外侧P<0.005)显著下降,对MSSA无此变化。
- 克林霉素浓度与置管时间或引流量无相关性,但即使置管5天后仅回收初始浓度的<20%。
- 利福平浓度快速显著下降,与置管时间(P<0.001)和脑脊液引流量(P=0.03)相关。
临床怎么用
- 临床应关注AI-EVD长期置管后抗菌活性下降及定植/感染风险。
- 置管时间和脑脊液引流量较大时,不宜过度依赖AI-EVD的抗菌预防作用。
局限性
- 仅评估了单一菌株挑战的体外抗菌活性,未直接关联临床感染结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Antibiotic-impregnated external ventricular drains (AI-EVDs) have a debated efficacy in clinical studies. OBJECTIVES: Our aim was to assess the durability of antimicrobial activity of AI-EVDs used in clinical settings. METHODS: From April 2017 to January 2018, all consecutive AI-EVDs (Bactiseal™) inserted in adult patients were prospectively included. After removal, each AI-EVD was cultured and assessed for antimicrobial activity on both internal and external sides of AI-EVDs. Catheters were each challenged with a single Staphylococcus strain [MSSA, MRSA or methicillin-resistant Staphylococcus epidermidis (MRSE)]. MS was used to measure residual concentrations of rifampicin and clindamycin. RESULTS: Sixty-five AI-EVDs were included (56 patients). Among these, 21 were challenged with MSSA, 23 with MRSA and 21 with MRSE. Five ventriculostomy-related colonizations (9%) and two ventriculostomy-related infections (4%) occurred. Staphylococcus was the main bacterium responsible for colonization (4/5). AI-EVD inhibition decreased significantly against MRSA and MRSE according to duration of catheterization (for external and internal sides, P < 0.02) and overall volume of CSF drained (P < 0.005 for both sides against MRSE, P < 0.005 for external side against MRSA), but not against MSSA. Clindamycin concentration was not correlated with duration of catheterization or CSF volume drained, but <20% of initial concentration was recovered even after 5 days of AI-EVD dwelling. Conversely, rifampicin concentration showed a rapid and significant decline correlated to duration and CSF volume (P < 0.001 and P = 0.03, respectively). CONCLUSIONS: Antimicrobial activity of AI-EVDs dropped quickly in vivo. Antimicrobial impregnation did not prevent AI-EVD colonization by susceptible strains in 9% of the cases.
引用
- Mounier R, Lang E, Hulin A, et al. Durability of antimicrobial activity of antibiotic-impregnated external ventricular drains: a prospective study. J Antimicrob Chemother. 2019. PMID: 31411688. doi:10.1093/jac/dkz335
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。