输入性疟疾诊断策略评估:显微镜、RDT与LAMP
在法国图卢兹医院开展前瞻性研究,纳入331例初筛疟疾患者,以qPCR为参考标准,比较薄厚血膜、QBC、RDT和LAMP五种方法的诊断性能。LAMP灵敏度97.3%,显著高于显微镜法(84.9%-86.3%)和RDT(86.3%);RDT对恶性疟灵敏度98.3%,但漏检所有卵形、三日和诺氏疟原虫。TnS+RDT+LAMP联合策略灵敏度达100%。
要点
- LAMP灵敏度97.3%,高于薄血膜(84.9%)和厚血膜(86.3%)
- RDT对恶性疟灵敏度98.3%,但漏检卵形、三日和诺氏疟原虫
- TnS+RDT+LAMP联合策略灵敏度100%,优于单纯显微镜策略
核心结论
- 在非流行国家,当前推荐的基于显微镜的疟疾诊断策略在考虑RDT和LAMP性能时似乎不令人满意,这两种快速敏感的检测只需有限培训。
研究设计与样本
- 前瞻性研究于2017年8月至2018年1月在图卢兹医院开展,纳入331例初始疟疾筛查患者,每份血样独立进行薄血膜、厚血膜、QBC、RDT和LAMP检测,并与qPCR参考标准比较。
主要发现
- qPCR检出73份疟原虫阳性样本,其中58份为恶性疟。
- LAMP灵敏度97.3%(71/73),薄血膜84.9%(62/73),厚血膜86.3%(63/73),QBC 86.3%(63/73),RDT 86.3%(63/73)。
- RDT对恶性疟灵敏度98.3%(57/58),但漏检所有卵形、三日和诺氏疟原虫感染。
- 所有方法特异性极好(99.6%-100%)。
- 最敏感的联合策略为TnS+RDT(95.9%,70/73)、TnS+LAMP(97.3%,71/73)和TnS+RDT+LAMP(100%,73/73),比单纯显微镜策略(厚血膜+薄血膜或QBC+薄血膜,均为87.7%,64/73)高约10%。
关键数值与推荐
- LAMP灵敏度97.3%(71/73),薄血膜84.9%(62/73),厚血膜86.3%(63/73),QBC 86.3%(63/73),RDT 86.3%(63/73)。
- RDT对恶性疟灵敏度98.3%(57/58),对卵形、三日和诺氏疟原虫灵敏度为0。
- 所有方法特异性99.6%-100%。
- TnS+RDT灵敏度95.9%(70/73),TnS+LAMP灵敏度97.3%(71/73),TnS+RDT+LAMP灵敏度100%(73/73)。
- 单纯显微镜策略厚血膜+薄血膜或QBC+薄血膜灵敏度均为87.7%(64/73)。
临床怎么用
- 在非流行国家诊断输入性疟疾时,可考虑采用RDT和LAMP等快速敏感检测,以弥补显微镜法的不足。
- 薄血膜仍是疟原虫虫种鉴定和定量的必要手段。
- 仅在LAMP阳性样本上追加薄血膜不降低TnS+LAMP策略的灵敏度。
局限性
- 研究为单中心前瞻性研究,样本来自非流行区医院,结果外推需谨慎。
- qPCR作为参考标准,可能存在假阴性或假阳性影响性能评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Malaria is one of most common tropical diseases encountered in travellers and migrants. It requires an urgent and reliable diagnosis considering its potential severity. In this study, performance of five diagnostic assays were evaluated in a nonendemic region and compared prospectively to quantitative PCR (qPCR). METHODS: A prospective study was conducted at Toulouse Hospital from August 2017 to January 2018 and included all patients with initial Plasmodium screening. Thin and thick blood smears (TnS, TkS), quantitative buffy coat (QBC), rapid diagnostic tests (RDTs) and commercial loop-mediated isothermal amplification (LAMP) were independently performed on each blood sample and compared to our qPCR reference standard. RESULTS: The study encompassed 331 patients, mainly returning from Africa. qPCR detected 73 Plasmodium-positive samples (including 58 falciparum). Individually, LAMP had a 97.3% (71/73) sensitivity, far ahead of TnS (84.9%, 62/73), TkS (86.3%, 63/73), QBC (86.3%, 63/73) and RDT (86.3%, 63/73). RDT demonstrated a high sensitivity for falciparum (98.3%, 57/58) but missed all ovale, malariae and knowlesi infections. Specificity was excellent for all techniques (99.6-100%). The most sensitive diagnosis strategies were TnS + RDT (95.9%, 70/73), TnS + LAMP (97.3%, 71/73) and TnS + RDT + LAMP (100%, 73/73), about 10% higher than strategies using exclusively microscopy, TkS + TnS (87.7%, 64/73) or QBC + TnS (87.7%, 64/73). TnS remains necessary for Plasmodium species identification and quantification. Adding sequentially TnS only on LAMP-positive samples did not decrease TnS + LAMP strategy sensitivity. CONCLUSIONS: In nonendemic countries, the currently recommended microscopy-based strategies seem unsatisfactory for malaria diagnosis considering RDT and LAMP performance, two rapid and sensitive assays that require limited training.
引用
- Charpentier E, Benichou E, Pagès A, et al. Performance evaluation of different strategies based on microscopy techniques, rapid diagnostic test and molecular loop-mediated isothermal amplification assay for the diagnosis of imported malaria. Clin Microbiol Infect. 2019. PMID: 31158521. doi:10.1016/j.cmi.2019.05.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。