新加坡某三级医院NDM-1阳性ST-308铜绿假单胞菌的克隆传播
研究调查了新加坡某三级医院2015年1月至2018年2月分离的298株泛β-内酰胺不敏感铜绿假单胞菌,发现31株(10.4%)为NDM阳性。全基因组测序显示所有NDM阳性株均属于克隆ST-308,blaNDM位于染色体整合接合元件ICETn43716385内,且NDM阳性株对多种药物耐药率更高,仅对黏菌素100%敏感。
要点
- 泛β-内酰胺不敏感铜绿假单胞菌中NDM阳性率为10.4%(31/298)。
- NDM阳性株均为ST-308克隆,blaNDM位于染色体ICETn43716385元件。
- NDM阳性株仅对黏菌素100%敏感,耐药率高于非NDM株。
核心结论
- 染色体突变、获得性耐药基因和毒力因子的组合可能促进了ST-308克隆在医院内的持续传播。
研究设计与样本
- 对新加坡某三级医院2015年1月至2018年2月分离的298株泛β-内酰胺不敏感铜绿假单胞菌进行NDM基因检测和基因组流行病学分析。
主要发现
- 298株泛β-内酰胺不敏感铜绿假单胞菌中31株(10.4%)为NDM阳性。
- 全基因组测序显示所有31株NDM阳性分离株均为克隆ST-308。
- blaNDM位于染色体整合接合元件ICETn43716385内。
- NDM阳性株携带丰富的细胞相关和分泌型毒力因子。
- NDM阳性株耐药率高于非NDM株,仅对黏菌素100%敏感。
关键数值与推荐
- NDM阳性率10.4%(31/298)。
- NDM阳性株对黏菌素敏感率100%。
临床怎么用
- 对泛β-内酰胺不敏感铜绿假单胞菌应关注NDM检测,黏菌素可能为NDM阳性株的有效选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: MDR Pseudomonas aeruginosa is a serious global threat to healthcare institutions. The mechanism by which drug resistance can be acquired is variable, but acquired carbapenemase production has been reported in P. aeruginosa. An investigation was performed to determine the rate and genomic epidemiology of New Delhi MBL (NDM) in β-lactam-non-susceptible isolates. METHODS: P. aeruginosa isolates from a tertiary hospital in Singapore between January 2015 and February 2018 were investigated for the presence of NDM genes. RESULTS: Out of 298 pan-β-lactam-non-susceptible isolates, 31 were found to be NDM positive (10.4%). WGS demonstrated that all 31 NDM-positive isolates were clonal, belonging to ST-308. blaNDM was chromosomally inserted within an integrative and conjugative element (ICE), ICETn43716385. The NDM-P. aeruginosa isolates possessed an extensive repertoire of both cell-associated [flagella, pili, alginate/biofilm, LPS, type III secretion system (T3SS) and type VI secretion system (T6SS)] and secreted virulence factors. Antibiograms revealed higher rates of drug resistance in NDM-positive isolates compared with their non-NDM counterparts. The NDM isolates remained 100% susceptible only to colistin. CONCLUSIONS: The combination of chromosomal mutations, acquired resistance genes and virulence factors likely facilitated the persistent and ongoing spread of the ST-308 clade of P. aeruginosa within the hospital. Our study illustrates the particular threat of NDM-positive P. aeruginosa in a tertiary hospital setting in the era of antimicrobial resistance.
引用
- Chew KL, Octavia S, Ng OT, et al. Challenge of drug resistance in Pseudomonas aeruginosa: clonal spread of NDM-1-positive ST-308 within a tertiary hospital. J Antimicrob Chemother. 2019. PMID: 31081022. doi:10.1093/jac/dkz169
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。