文献速递结核与非结核分枝杆菌医院感染防控

美国俄勒冈州非结核分枝杆菌关节假体感染暴发(2010-2016)

Outbreak of Nontuberculous Mycobacteria Joint Prosthesis Infections, Oregon, USA, 2010-2016.
PubMed 文献 · Emerg Infect Dis · 2019-01-01

调查2010-2014年发生的偶发分枝杆菌与goodii分枝杆菌假体关节手术部位感染聚集事件,通过病例搜索、病历回顾、访谈、手术观察、匹配病例对照研究、脉冲场凝胶电泳及环境调查识别9例病例,其中6例在术后90天以上确诊。病例与手术器械厂商代表在手术室在场相关,其他潜在来源被排除;2016年发生第10例。

要点

  • 手术室人员(含厂商代表)应遵守感染控制指南
  • 疑似分枝杆菌感染应尽早采集培养样本
  • 术后90天监测可能漏诊生长缓慢病原体所致手术部位感染

核心结论

  • 该非结核分枝杆菌假体关节感染聚集与手术器械厂商代表在手术室在场相关,其他潜在来源被排除。

研究设计与样本

  • 病例定义为2010年10月1日或之后行关节置换术后1年内发生的培养阳性非结核分枝杆菌手术部位感染;通过病例搜索、病历回顾、访谈、手术观察、匹配病例对照研究、分离株脉冲场凝胶电泳及环境调查识别病例。

主要发现

  • 共识别9例病例,其中6例在术后90天以上确诊;2016年发生第10例病例。

关键数值与推荐

  • 病例为培养阳性非结核分枝杆菌手术部位感染,发生于2010年10月1日或之后关节置换术后1年内;6例确诊时间晚于术后90天。

临床怎么用

  • 所有进入手术室人员应遵循感染控制指南;疑似分枝杆菌感染应尽早采集培养样本;术后90天监测可能漏诊需特殊培养的缓慢生长病原体所致手术部位感染。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

We investigated a cluster of Mycobacterium fortuitum and M. goodii prosthetic joint surgical site infections occurring during 2010-2014. Cases were defined as culture-positive nontuberculous mycobacteria surgical site infections that had occurred within 1 year of joint replacement surgery performed on or after October 1, 2010. We identified 9 cases by case finding, chart review, interviews, surgical observations, matched case-control study, pulsed-field gel electrophoresis of isolates, and environmental investigation; 6 cases were diagnosed >90 days after surgery. Cases were associated with a surgical instrument vendor representative being in the operating room during surgery; other potential sources were ruled out. A tenth case occurred during 2016. This cluster of infections associated with a vendor reinforces that all personnel entering the operating suite should follow infection control guidelines; samples for mycobacterial culture should be collected early; and postoperative surveillance for <90 days can miss surgical site infections caused by slow-growing organisms requiring specialized cultures, like mycobacteria.

来源:Emerg Infect Dis,查看原文。版权归原作者所有。

引用

  1. Buser GL, Laidler MR, Cassidy PM, et al. Outbreak of Nontuberculous Mycobacteria Joint Prosthesis Infections, Oregon, USA, 2010-2016. Emerg Infect Dis. 2019. PMID: 31002056. doi:10.3201/eid2505.181687

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。