文献速递病毒性肝炎

ARFI弹性成像在丙肝病毒清除后肝纤维化分期中的性能

Performance of Acoustic Radiation Force Impulse Elastography for Staging Liver Fibrosis in Patients With Chronic Hepatitis C After Viral Eradication.
PubMed 文献 · Clin Infect Dis · 2020-01-01

该研究基于组织学验证,前瞻性纳入644例慢性丙型肝炎患者,分别于治疗基线或SVR后3年接受ARFI弹性成像与肝活检。ARFI弹性成像在病毒清除后肝纤维化分期中表现出良好性能。

要点

  • SVR后肝硬度值显著低于治疗前,但纤维化分期分布无显著变化。
  • SVR后组区分F1 vs F2-4、F1-2 vs F3-4、F1-3 vs F4的cutoff分别为1.22、1.59、1.75 m/s。
  • ARFI弹性成像可用于病毒清除后肝纤维化分期的无创评估。

核心结论

  • ARFI弹性成像在慢性丙肝病毒清除后、炎症消退的组织学上确定肝纤维化分期具有良好应用前景。

研究设计与样本

  • 前瞻性研究,连续筛选并分析644例接受ARFI弹性成像和经皮肝活检的慢性丙型肝炎患者。
  • 521例(80.9%)在治疗基线活检,123例(19.1%)在SVR后中位3年(IQR 0.1)活检。

关键数值与推荐

  • 治疗前组区分F1 vs F2-F4、F1-F2 vs F3-F4、F1-F3 vs F4的cutoff分别为1.47(AUC 0.8333,95%CI 0.7981-0.8663)、1.81(AUC 0.8763,95%CI 0.8376-0.9107)、1.86(AUC 0.8811,95%CI 0.8378-0.9179)m/s。
  • SVR后组对应cutoff分别为1.22(AUC 0.7872,95%CI 0.7001-0.8624)、1.59(AUC 0.8808,95%CI 0.8034-0.9422)、1.75(AUC 0.9018,95%CI 0.8201-0.9644)m/s。

临床怎么用

  • 在丙肝病毒清除后,可采用ARFI弹性成像进行无创肝纤维化分期,但需注意SVR后LS值普遍降低,应参考SVR后组的cutoff值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Data on noninvasive liver fibrosis staging after viral eradication are unclear. This histology-based study validated the performance of liver stiffness (LS) measurements after viral eradication. METHODS: Consecutive participants with chronic hepatitis C (CHC) who received concomitant LS measurements through acoustic radiation force impulse (ARFI) elastography and percutaneous liver biopsy were prospectively screened and analyzed. RESULTS: Of the 644 patients, 521 (80.9%) underwent a biopsy at treatment baseline, and the remaining 123 (19.1%) underwent a biopsy at 3 years (median; interquartile range, 0.1) after the sustained virological response (SVR) to pegylated interferon-based and direct-acting antiviral treatments. The proportions of histological fibrosis stages did not differ significantly between the pretreatment and post-SVR groups (P = .0615). However, the LS values differed significantly (P < .0001). The median LS values (presented as shear wave velocities in meters per second) were 1.51 (0.92) for the pretreatment group and 1.22 (0.77) for the post-SVR group. The cutoffs (areas under the receiver operating characteristic curve, obtained using the bootstrap method) to dichotomize between METAVIR fibrosis stage F1 versus stages F2-F4, F1-F2 versus F3-F4, and F1-F3 versus F4 were 1.47 (0.8333, 95% confidence interval [CI] 0.7981-0.8663), 1.81 (0.8763, 95% CI 0.8376-0.9107), and 1.86 (0.8811, 95% CI 0.8378-0.9179) in the pretreatment group, respectively, and 1.22 (0.7872, 95% CI 0.7001-0.8624), 1.59 (0.8808, 95% CI 0.8034-0.9422), and 1.75 (0.9018, 95% CI 0.8201-0.9644) in the post-SVR group, respectively. CONCLUSIONS: The performance of LS measurements through ARFI elastography is promising to determine the liver fibrosis stage on necroinflammation-resolved histology in CHC after viral eradication.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Chen SH, Lai HC, Chiang IP, et al. Performance of Acoustic Radiation Force Impulse Elastography for Staging Liver Fibrosis in Patients With Chronic Hepatitis C After Viral Eradication. Clin Infect Dis. 2020. PMID: 30816416. doi:10.1093/cid/ciz161

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。