干扰素γ诱导蛋白10诊断潜伏性结核感染的准确性:系统评价与荟萃分析
该系统评价与荟萃分析检索多个数据库至2018年6月,纳入12项研究共1023名参与者和1122份样本,评估IP-10对比TST和IGRA诊断LTBI的准确性。合并敏感度0.85、特异度0.89、DOR 44.23,提示IP-10是诊断LTBI有前景的生物标志物。
要点
- IP-10诊断LTBI合并敏感度0.85、特异度0.89。
- 合并DOR为44.23,提示诊断准确性较高。
- 高负担国家等因素未能解释异质性(p>0.05)。
核心结论
- IP-10是诊断潜伏性结核感染的有前景生物标志物。
研究设计与样本
- 系统评价与荟萃分析,检索PubMed、Embase、Cochrane Library和Web of Science至2018年6月。
- 纳入12项研究,共1023名参与者和1122份样本。
- 纳入队列、病例对照和横断面研究,比较IP-10与TST和IGRA诊断LTBI。
主要发现
- IP-10诊断LTBI的合并敏感度为0.85(95%CI 0.80-0.88)。
- 合并特异度为0.89(95%CI 0.84-0.92)。
- 合并PLR为7.55(95%CI 5.20-10.97),NLR为0.17(95%CI 0.13-0.22)。
- 合并DOR为44.23(95%CI 28.86-67.79),提示诊断准确性较高。
- meta回归显示高负担国家、研究设计、IP-10方法、参考标准和IP-10 cut-off均不能解释异质性(p>0.05)。
临床怎么用
- IP-10可作为LTBI诊断的辅助生物标志物,但需结合临床背景解读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Effective diagnostic methods for detecting latent tuberculosis infection (LTBI) are important for its eradication. A number of studies have evaluated the use of interferon-γ-induced protein 10 (IP-10), which is elevated after tuberculosis infection, as a biomarker for LTBI, but conclusive results regarding its effectiveness have not been reported. OBJECTIVES: Our objective was to assess the diagnostic value of IP-10 for LTBI. DATA SOURCES: We searched the PubMed, Embase, the Cochrane Library and Web of Science databases to find eligible studies. STUDY ELIGIBILITY CRITERIA: We included cohort, case-control and cross-sectional studies that evaluated IP-10 in LTBI participants in comparison with tuberculin skin tests (TST) and interferon-γ release assays (IGRA). PARTICIPANTS: Individuals with LTBI and uninfected participants. INTERVENTIONS: IP-10 (index test) compared with TST and IGRA (reference standard) for diagnosing LTBI. METHODS: PubMed, Embase, the Cochrane Library, and Web of Science databases were searched up to June 2018. A hierarchical summary receiver operating characteristic (HSROC) model was used to evaluate the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and HSROC curve for the diagnostic efficiency of IP-10. RESULTS: Twelve studies including 1023 participants and 1122 samples were included. The overall pooled sensitivity was 0.85 (95% CI 0.80-0.88), specificity was 0.89 (95% CI 0.84-0.92), PLR was 7.55 (95% CI 5.20-10.97), NLR was 0.17 (95% CI 0.13-0.22) and DOR was 44.23 (95% CI 28.86-67.79), indicating a high accuracy for diagnosing LTBI. Based on a meta-regression analysis, high-burden countries, study design, IP-10 method, reference standard and the IP-10 cut-off could not explain the heterogeneity (p >0.05). CONCLUSIONS: Our results suggested that IP-10 is a promising biomarker for the diagnosis of LTBI.
引用
- Qiu X, Tang Y, Yue Y, et al. Accuracy of interferon-γ-induced protein 10 for diagnosing latent tuberculosis infection: a systematic review and meta-analysis. Clin Microbiol Infect. 2018. PMID: 30553864. doi:10.1016/j.cmi.2018.12.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。