文献速递新发突发、热带与寄生虫病

基于超敏诊断的无症状疟疾患病率与流行病学特征:横断面研究

Prevalence and Epidemiological Characteristics of Asymptomatic Malaria Based on Ultrasensitive Diagnostics: A Cross-sectional Study.
PubMed 文献 · Clin Infect Dis · 2019-01-01

该横断面研究纳入562名无症状个体,以qRT-PCR为参考标准比较多种疟疾诊断方法的灵敏度,并分析无症状疟疾与血红蛋白的关联。结果显示LAMP灵敏度最高(92.6%),uRDT Alere Malaria次之(33.9%);无症状疟疾患病率每增加3.2%,血红蛋白下降1 g/dL。超敏诊断可为消除疟疾提供准确的无症状感染患病率估计。

要点

  • LAMP检测无症状疟疾的灵敏度最高(92.6%),优于uRDT和常规RDT。
  • uRDT Alere Malaria灵敏度(33.9%)优于CareStart(14.1%)和显微镜(5.0%)。

核心结论

  • LAMP检测无症状疟疾的灵敏度高于uRDT Alere Malaria、CareStart、显微镜和SD Bioline。
  • 超敏诊断可提供消除疟疾所需的无症状疟疾准确患病率估计。

研究设计与样本

  • 横断面研究,纳入562名无症状个体,以qRT-PCR为参考标准比较RDT、LAMP和qRT-PCR的检测性能。

主要发现

  • 以qRT-PCR为参考,LAMP灵敏度92.6%(95%CI 86.4-96.5),uRDT Alere Malaria 33.9%(95%CI 25.5-43.1)。
  • CareStart Malaria灵敏度14.1%(95%CI 8.4-21.5),显微镜和SD Bioline均为5.0%(95%CI 1.8-10.5)。
  • 仅针对恶性疟原虫标本,uRDT Alere Malaria灵敏度50.0%(95%CI 38.8-61.3),SD Bioline 7.3%(95%CI 2.7-15.3)。
  • hrp2基因缺失率为4.8%。

临床怎么用

  • 在疟疾消除阶段,对无症状人群筛查可优先考虑LAMP等高灵敏度方法。
  • uRDT Alere Malaria在常规RDT中灵敏度较高,但仍低于LAMP。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: As the global public-health objectives for malaria evolve from malaria control towards malaria elimination, there is increasing interest in the significance of asymptomatic infections and the optimal diagnostic test to identify them. METHOD: We conducted a cross-sectional study of asymptomatic individuals (N = 562) to determine the epidemiological characteristics associated with asymptomatic malaria. Participants were tested by rapid diagnostic tests (CareStart, Standard Diagnostics [SD] Bioline, and Alere ultrasensitive RDT [uRDT]), loop-mediated isothermal amplification (LAMP), and quantitative reverse transcription polymerase chain reaction (qRT-PCR) to determine malaria positivity. Hemoglobin values were recorded, and anemia was defined as a binary variable, according to World Health Organization guidelines. RESULTS: Compared to reference qRT-PCR, LAMP had the highest sensitivity (92.6%, 95% confidence interval [CI] 86.4-96.5), followed by uRDT Alere Malaria (33.9%, 95% CI 25.5-43.1), CareStart Malaria (14.1%, 95% CI 8.4-21.5), microscopy (5.0%, 95% CI 1.8-10.5), and SD Bioline (5.0%, 95% CI 1.8-10.5). For Plasmodium falciparum specimens only, the sensitivity for uRDT Alere Malaria was 50.0% (95% CI 38.8-61.3) and SD Bioline was 7.3% (95% CI 2.7-15.3). Based on multivariate regression analysis with qRT-PCR as the gold standard, for every 3.2% increase in the prevalence of asymptomatic malaria, hemoglobin decreased by 1 gram per deciliter (prevalence ratio 0.968, 95% CI 0.940-0.997; P = .032). Deletions (4.8%) in hrp2 were noted. CONCLUSIONS: While uRDT Alere Malaria has superior sensitivity to rapid diagnostic tests and microscopy in detecting asymptomatic malaria, LAMP is superior still. Ultrasensitive diagnostics provide the accurate prevalence estimates of asymptomatic malaria required for elimination.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Girma S, Cheaveau J, Mohon AN, et al. Prevalence and Epidemiological Characteristics of Asymptomatic Malaria Based on Ultrasensitive Diagnostics: A Cross-sectional Study. Clin Infect Dis. 2019. PMID: 30475992. doi:10.1093/cid/ciy1005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。