两种反向梅毒检测算法诊断梅毒的分析:一项大型队列前瞻性研究
该前瞻性研究纳入119891份血清样本,以化学发光免疫分析初筛,比较美国CDC与欧洲CDC推荐的两种反向梅毒检测算法的一致性。两种算法总体符合率为99.996%,κ值为0.999,梅毒阳性率分别为1.43%和1.42%,提示在低流行人群中性能相当。
要点
- 两种算法总体符合率99.996%,κ值0.999,一致性极高。
- 美国CDC算法阳性率1.43%,欧洲CDC算法阳性率1.42%。
- 在低流行人群中,两种反向梅毒检测算法性能相当。
核心结论
- 研究结果表明,在低流行人群中,美国CDC推荐算法与欧洲CDC推荐算法在梅毒筛查方面性能相当。
研究设计与样本
- 前瞻性研究,纳入119891名受试者的119891份血清样本,来自中国第六大医院,每份样本均以化学发光免疫分析(CIA)初筛,CIA反应性样本同时进行RPR和TPPA检测。
主要发现
- 两种算法总体符合率为99.996%,κ值为0.999。
- 美国CDC推荐算法确定的梅毒阳性率为1.43%,欧洲CDC推荐算法为1.42%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Two serologic syphilis screening algorithms recommended by the US Centers for Disease Control and Prevention (US CDC) and the European Centre for Disease Prevention and Control (ECDC), respectively, are commonly used for syphilis screening; however, which one is optimal remains to be determined. METHODS: We conducted a prospective study of 119891 subjects to analyze the consistency of the US CDC- and ECDC-recommended algorithms. The US CDC-recommended algorithm begins with a treponemal immunoassay, followed by a rapid plasma reagin (RPR) test. RPR-nonreactive samples are confirmed by the Treponema pallidum particle agglutination assay (TPPA). The ECDC-recommended algorithm begins with a treponemal immunoassay, followed by a confirmatory treponemal test. If the confirmatory test is reactive, a quantitative nontreponemal assay is used to assess the disease activity and treatment response. In the present study, a total of 119891 serum samples from a large hospital (sixth largest in China) were included, and each sample was screened with a chemiluminescent immunoassay (CIA). CIA-reactive samples were then simultaneously tested with RPR and TPPA. The consistency of these 2 algorithms was determined by calculating the percentage of agreement and κ coefficient. RESULTS: The overall percentage of agreement and κ value between these 2 algorithms were 99.996% and 0.999, respectively. The positivity rate for syphilis as determined by the US CDC- and ECDC-recommended algorithms was 1.43% and 1.42%, respectively. CONCLUSIONS: Our results suggest that the US CDC-recommended algorithm and the ECDC-recommended algorithm have comparable performances for syphilis screening in low-prevalence populations.
引用
- Peng J, Lu Y, Yu H, et al. Analysis of 2 Reverse Syphilis Testing Algorithms in Diagnosis of Syphilis: A Large-Cohort Prospective Study. Clin Infect Dis. 2018. PMID: 30059969. doi:10.1093/cid/ciy198
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。