文献速递细菌感染、耐药与抗菌药物

自动化延时显微镜:筛查多重耐药革兰阴性菌抗生素联合效果的新方法

Automated time-lapse microscopy a novel method for screening of antibiotic combination effects against multidrug-resistant Gram-negative bacteria.
PubMed 文献 · Clin Microbiol Infect · 2017-11-03

本研究评估基于延时显微成像的自动化方法(oCelloScope)在体外测定产碳青霉烯酶肠杆菌目(CPE)抗生素联合效果中的可行性。将4株肺炎克雷伯菌和2株大肠埃希菌暴露于黏菌素、美罗培南、利福平及替加环素单用与联合,以24小时背景校正吸光度(BCA)≤8作为抑制细菌生长的初筛界值。结果显示36种方案中12种呈协同,BCA≤8与24小时菌浓度≤6 log10 CFU/mL一致,联合效果分类在33/36方案中与时间杀菌曲线结果相符。该方法可准确判定联合效果,较时间杀菌试验高效,信息量优于棋盘法。

要点

  • BCA≤8(24h)与菌浓度≤6 log10 CFU/mL一致,可作为生长抑制初筛界值
  • 36种联合方案中12种呈协同,以黏菌素联合利福平最常见
  • 联合效果分类与时间杀菌曲线在33/36方案中一致,3例因对象计数低无法分类

核心结论

  • 自动化延时显微镜可准确判定抗生素联合效果,较时间杀菌试验高效,信息量优于棋盘法,有助于加速筛查对多重耐药革兰阴性菌有活性的联合方案。

研究设计与样本

  • 体外研究,采用4株肺炎克雷伯菌和2株大肠埃希菌,暴露于黏菌素、美罗培南、利福平及替加环素单用与联合,并与静态时间杀菌试验比较。

主要发现

  • 时间杀菌试验显示36种方案中12种呈协同,以黏菌素联合利福平最常见。
  • BCA≤8(24h)与24小时菌浓度≤6 log10 CFU/mL一致。
  • 联合效果分类与时间杀菌结果在33/36方案中相符;3例因对象计数低无法分类。

关键数值与推荐

  • oCelloScope实验中以24小时背景校正吸光度(BCA)≤8作为抑制细菌生长的初筛界值。
  • 基于图像中对象(细菌)数量判定协同、无关与拮抗。

临床怎么用

  • 该方法可用于加速筛查对多重耐药革兰阴性菌有活性的抗生素联合方案,尤适用于产碳青霉烯酶肠杆菌目(CPE)。

局限性

  • 3例因对象计数低无法分类联合效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Antibiotic combinations are often used for carbapenemase-producing Enterobacteriaceae (CPE) but more data are needed on the optimal selection of drugs. This study aimed to evaluate the feasibility of a novel automated method based on time-lapse microscopy (the oCelloScope, Philips BioCell A/S, Allerød, Denmark) to determine in vitro combination effects against CPE and to discuss advantages and limitations of the oCelloScope in relation to standard methods. METHODS: Four Klebsiella pneumoniae and two Escherichia coli were exposed to colistin, meropenem, rifampin and tigecycline, alone and in combination. In the oCelloScope experiments, a background corrected absorption (BCA) value of ≤8 at 24 h was used as a primary cut-off indicating inhibition of bacterial growth. A new approach was used to determine synergy, indifference and antagonism based on the number of objects (bacteria) in the images. Static time-kill experiments were performed for comparison. RESULTS: The time-kill experiments showed synergy with 12 of 36 regimens, most frequently with colistin plus rifampin. BCA values ≤8 consistently correlated with 24-h bacterial concentrations ≤6 log10 CFU/mL. The classification of combination effects agreed with the time-kill results for 33 of 36 regimens. In three cases, the interactions could not be classified with the microscopy method because of low object counts. CONCLUSIONS: Automated time-lapse microscopy can accurately determine the effects of antibiotic combinations. The novel method is highly efficient compared with time-kill experiments, more informative than checkerboards and can be useful to accelerate the screening for combinations active against multidrug-resistant Gram-negative bacteria.

来源:Clin Microbiol Infect,查看原文。版权归原作者所有。

引用

  1. Ungphakorn W, Lagerbäck P, Nielsen EI, et al. Automated time-lapse microscopy a novel method for screening of antibiotic combination effects against multidrug-resistant Gram-negative bacteria. Clin Microbiol Infect. 2017. PMID: 29108951. doi:10.1016/j.cmi.2017.10.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。