PointFinder:基于全基因组测序检测细菌染色体点突变相关耐药的新型网络工具
该研究对150株沙门菌、大肠埃希菌和空肠弯曲菌进行表型药敏试验,并比较PointFinder(BLAST法)与内部方法(原始读段比对)检测染色体点突变的结果。针对喹诺酮类、多粘菌素、利福平、大环内酯类和四环素类耐药相关的685项表型试验,预测与表型一致率达98.4%。PointFinder是一款用户友好的网络工具,可用于检测染色体点突变相关耐药。
要点
- PointFinder基于BLAST检测染色体点突变相关耐药,与表型药敏一致率达98.4%。
- 使用Velvet组装时检出pmrB V161G突变,但SPAdes组装或读段比对未检出。
核心结论
- PointFinder是一款用户友好、可检测染色体点突变相关耐药的网络工具,预测与表型药敏高度一致。
研究设计与样本
- 对150株沙门菌、大肠埃希菌和空肠弯曲菌进行表型药敏试验,并比较PointFinder与内部读段比对法的检测结果。
主要发现
- 685项针对喹诺酮类、多粘菌素、利福平、大环内酯类和四环素类染色体耐药的药敏试验中,预测与表型一致率为98.4%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Antibiotic resistance is a major health problem, as drugs that were once highly effective no longer cure bacterial infections. WGS has previously been shown to be an alternative method for detecting horizontally acquired antimicrobial resistance genes. However, suitable bioinformatics methods that can provide easily interpretable, accurate and fast results for antimicrobial resistance associated with chromosomal point mutations are still lacking. METHODS: Phenotypic antimicrobial susceptibility tests were performed on 150 isolates covering three different bacterial species: Salmonella enterica, Escherichia coli and Campylobacter jejuni. The web-server ResFinder-2.1 was used to identify acquired antimicrobial resistance genes and two methods, the novel PointFinder (using BLAST) and an in-house method (mapping of raw WGS reads), were used to identify chromosomal point mutations. Results were compared with phenotypic antimicrobial susceptibility testing results. RESULTS: A total of 685 different phenotypic tests associated with chromosomal resistance to quinolones, polymyxin, rifampicin, macrolides and tetracyclines resulted in 98.4% concordance. Eleven cases of disagreement between tested and predicted susceptibility were observed: two C. jejuni isolates with phenotypic fluoroquinolone resistance and two with phenotypic erythromycin resistance and five colistin-susceptible E. coli isolates with a detected pmrB V161G mutation when assembled with Velvet, but not when using SPAdes or when mapping the reads. CONCLUSIONS: PointFinder proved, with high concordance between phenotypic and predicted antimicrobial susceptibility, to be a user-friendly web tool for detection of chromosomal point mutations associated with antimicrobial resistance.
引用
- Zankari E, Allesøe R, Joensen KG, et al. PointFinder: a novel web tool for WGS-based detection of antimicrobial resistance associated with chromosomal point mutations in bacterial pathogens. J Antimicrob Chemother. 2017. PMID: 29091202. doi:10.1093/jac/dkx217
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。