文献速递细菌感染、耐药与抗菌药物医院感染防控

新型综合干预措施包括改造卫生与供水系统控制异基因造血干细胞移植受者多重耐药铜绿假单胞菌

Control of Multidrug-Resistant Pseudomonas aeruginosa in Allogeneic Hematopoietic Stem Cell Transplant Recipients by a Novel Bundle Including Remodeling of Sanitary and Water Supply Systems.
PubMed 文献 · Clin Infect Dis · 2017-01-01

本研究在异基因造血干细胞移植病房重建期间实施卫生设施改造(新型淋浴排水、消毒虹吸、无框马桶),并追踪2012-2014年MDRPa定植/感染患者及环境监测。结果显示2014年MDRPa affected患者从31例降至3例,感染相关病死率从3.6%降至0%,环境检出率下降,全基因组测序证实环境与患者分离株高度同源。

要点

  • 卫生与供水系统改造可显著减少MDRPa环境储源及患者定植/感染。
  • 2014年MDRPa affected患者降至3例且无感染,相关病死率从3.6%降至0%。
  • 环境与临床分离株全基因组测序显示高度同源,支持环境传播。

核心结论

  • 针对环境污染的医院建设措施可有效降低高致死性MDRPa感染风险。

研究设计与样本

  • 在2011年4月至2014年4月移植病房重建期间实施技术修改,2012-2014年追踪MDRPa affected患者及环境 occurrence,并对菌株进行全基因组测序。

主要发现

  • 2012和2013年共31例(9.2%;18定植,13感染)患者affected,2014年降至3例(17%;3定植,0感染)。
  • MDRPa致死率从3.6%降至0%。
  • 厕所环境MDRPa检出率从2012-2013年的18.9%降至次年6.1%,淋浴出口从8.1%降至3.0%。
  • 全基因组测序显示环境与患者分离株亲缘关系密切。

临床怎么用

  • 在HSCT病房可考虑改造卫生与供水系统(如新型淋浴排水、消毒虹吸、无框马桶)作为感染控制综合措施的一部分。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Infections by multidrug-resistant Pseudomonas aeruginosa (MDRPa) are an important cause of morbidity and mortality in patients after allogeneic hematopoietic stem cell transplantation (HSCT). Humid environments can serve as a reservoir and source of infection by this pathogen. To minimize the risk of infection from these reservoirs, we performed extensive remodeling of sanitation and water installations as the focus of our hygiene bundle. METHODS: During the reconstruction of our transplantation unit (April 2011-April 2014) we implemented several technical modifications to reduce environmental contamination by and subsequent spreading of MDRPa, including a newly designed shower drain, disinfecting siphons underneath the sinks, and rimless toilets. During a 3-year study period (2012-2014), we tracked the number of patients affected by MDRPa (colonized and/or infected) and the outcome of infected patients, and monitored the environmental occurrence of this pathogen. We further performed whole-genome sequencing of nosocomial MDRPa strains to evaluate genotypic relationships between isolates. RESULTS: Whereas 31 (9.2%; 18 colonized, 13 infected) patients were affected in 2012 and 2013, the number decreased to 3 in 2014 (17%; 3 colonized, 0 infected). Lethality by MDRPa similarly decreased from 3.6% to 0%. Environmental detection of MDRPa decreased in toilets from 18.9% in 2012-2013 to 6.1% in the following year and from 8.1% to 3.0%, respectively, in shower outlets. Whole-genome sequencing showed close relationships between environmental and patient-derived isolates. CONCLUSIONS: Hospital construction measures aimed at controlling environmental contamination by and spread of MDRPa are effective at minimizing the risk of highly lethal MDRPa infections.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Kossow A, Kampmeier S, Willems S, et al. Control of Multidrug-Resistant Pseudomonas aeruginosa in Allogeneic Hematopoietic Stem Cell Transplant Recipients by a Novel Bundle Including Remodeling of Sanitary and Water Supply Systems. Clin Infect Dis. 2017. PMID: 28520856. doi:10.1093/cid/cix465

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。