文献速递新发突发、热带与寄生虫病医院感染防控

Metofluthrin空间挥发器减少巴布亚新几内亚人蚊接触的效果

Efficacy of Metofluthrin Spatial Emanators to Reduce Human Vector Contact in Papua New Guinea.
PubMed 文献 · J Infect Dis · 2026-06-25

在巴布亚新几内亚2个村庄评估SumiOne™空间挥发器(SE)的昆虫学效果:室内单独或室内外半封闭区域联合放置,每干预组12户,经8周人饵诱捕和哨兵笼生物测定与对照组比较。室内人蚊接触显著降低,两种干预方式保护效力60%-80%持续5-6周,每周约下降6%-7%;室外接触无显著降低。室内哨兵笼24小时死亡率>80%持续7周,60分钟击倒和抑制刺探完全持续8周。

要点

  • SumiOne™ SE可显著降低室内人蚊接触,保护效力60%-80%持续5-6周
  • 室外人蚊接触未见显著降低
  • 室内哨兵笼24小时死亡率>80%持续7周,完全击倒和抑制刺探持续8周

核心结论

  • SumiOne™ SE大幅减少室内蚊虫暴露,可作为ITN的补充用于巴新疟疾防控,但需提升持久性和室外效果。

研究设计与样本

  • 在巴布亚新几内亚2个村庄开展现场评估,SE仅室内放置或室内外半封闭区域联合放置,每干预组12户,设对照组。
  • 采用人饵诱捕和哨兵笼生物测定,持续8周并与对照组比较。

主要发现

  • 两种干预方式室内人蚊接触保护效力均为60%-80%,持续5-6周,之后每周约下降6%-7%。
  • 室外人蚊接触未检测到显著降低。
  • 室内哨兵笼24小时死亡率>80%持续7周,60分钟击倒和抑制刺探完全持续8周。

关键数值与推荐

  • 室内保护效力60%-80%持续5-6周,每周下降约6%-7%。
  • 室内哨兵笼24小时死亡率>80%持续7周,60分钟击倒和抑制刺探完全持续8周。

临床怎么用

  • 在巴新等疟疾传播地区,可将SumiOne™ SE作为ITN的补充工具降低室内蚊虫暴露。
  • 需关注其保护效力随时间下降,室外暴露未显著降低,应结合其他室外防护措施。

局限性

  • 原文未报告样本量、P值等详细统计信息;仅2个村庄、每干预组12户,外推需谨慎。
  • 室外人蚊接触无显著降低,SE持久性有限(约5-6周后效力下降)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Alternative vector control tools are needed to address rising malaria burden in Papua New Guinea (PNG), where outdoor transmission and reduced insecticidal efficacy of insecticide-treated nets (ITNs) create persistent protection gaps. Volatile pyrethroid spatial emanators (SEs) release active ingredients that deter or kill mosquitoes, and 2 SE products have recently been WHO prequalified for malaria vector control. METHODS: We evaluated the entomological efficacy of SumiOne™ SEs in 2 villages in PNG. Spatial emanators were installed indoors only or both indoors and outdoors in semi-enclosed peridomestic spaces, with 12 houses per intervention arm. Human landing catches and sentinel cage bioassays were conducted over 8 weeks and compared with a control arm. RESULTS: Human-vector contact was significantly reduced indoors, with a protective efficacy of 60%-80% in both intervention arms for 5-6 weeks, declining at approximately 6%-7% per week. No significant reduction in outdoor human-vector contact was detected. Indoor sentinel cage bioassays showed >80% 24-hour mortality for 7 weeks, and complete 60 minute knockdown and inhibition of probing for 8 weeks. CONCLUSIONS: SumiOne™ SEs substantially reduced indoor mosquito exposure and may complement ITNs for malaria control in PNG. Future research should prioritize increased longevity and stronger outdoor impact.

来源:J Infect Dis,查看原文。版权归原作者所有。

引用

  1. Katusele M, Johnson P, Omera E, et al. Efficacy of Metofluthrin Spatial Emanators to Reduce Human Vector Contact in Papua New Guinea. J Infect Dis. 2026. PMID: 42347557. doi:10.1093/infdis/jiag298

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。