文献速递细菌感染、耐药与抗菌药物医院感染防控新发突发、热带与寄生虫病

快速分子鉴别新德里金属β-内酰胺酶关键变异体

Rapid molecular differentiation of key New Delhi metallo-β-lactamase variants in a setting with emerging high-risk clones.
PubMed 文献 · Clin Microbiol Infect · 2026-06-02

研究开发并评估了一种多重实时PCR方法,靶向blaNDM的两个多态性位点(389和460),用于快速区分NDM-1、NDM-5和NDM-14。使用60株经全基因组测序确认的产NDM菌株(各20株)和10株非NDM阴性对照,结果显示各变异体具有特异的扩增模式,所有非NDM菌株检测阴性。该方法可在特定流行病学背景下快速准确鉴别关键blaNDM变异体,为实时监测和暴发管理提供测序之外的实用替代方案。

要点

  • 基于ΔCt值的多重实时PCR可区分NDM-1、NDM-5和NDM-14。
  • NDM-5在460位点VIC信号缺失,NDM-14在389位点ΔCt显著偏移。
  • 所有非NDM菌株检测阴性,方法特异性良好。

核心结论

  • 该多重实时PCR方法能在特定流行病学背景下快速准确区分关键的blaNDM变异体,为实时监测和暴发管理提供测序之外的实用替代方案。

研究设计与样本

  • 研究设计并评估了一种靶向blaNDM两个多态性位点(389和460)的多重实时PCR方法,在CFX96系统上标准化扩增。
  • 评估使用60株经全基因组测序确认的产NDM菌株(20株NDM-1、20株NDM-5、20株NDM-14)和10株非NDM阴性对照。

主要发现

  • NDM-1在389和460位点的ΔCt均值分别为0.15±0.20和0.05±0.10,通道间差异极小。
  • NDM-14在389位点ΔCt均值4.2±0.5,460位点差异可忽略。
  • NDM-5在460位点VIC信号缺失,389位点ΔCt均值0.05±0.15。
  • 所有非NDM分离株检测阴性。

关键数值与推荐

  • 基于ΔCt值(VIC Ct减去FAM Ct)区分亚型:NDM-1双位点ΔCt接近0,NDM-14在389位点ΔCt约4.2,NDM-5在460位点VIC信号缺失。

临床怎么用

  • 可用于实时监测和暴发管理,快速鉴别NDM-1、NDM-5和NDM-14,辅助早期发现高风险克隆并支持针对性感染控制策略。

局限性

  • 方法仅在特定流行病学背景下评估,针对NDM-1、NDM-5和NDM-14三种变异体,未涵盖其他blaNDM变异体。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The increasing dissemination of bla-New Delhi metallo-β-lactamase (NDM) among high-risk clones and the lack of rapid methods to distinguish between its variants limit real-time epidemiological surveillance and timely infection control responses. This study aimed to develop and evaluate a real-time PCR assay for the rapid differentiation of the most prevalent blaNDM variants (NDM-1, NDM-5, and NDM-14) circulating in our setting. METHODS: A multiplex real-time PCR assay targeting 2 polymorphic positions (389 and 460) of blaNDM was designed using reference sequences (FN396876.1, JN104597.1, and KM210086.1). Amplification was performed on a CFX96 system under standardized conditions. The assay was evaluated using 60 well-characterized NDM-producing isolates (20 NDM-1, 20 NDM-5, and 20 NDM-14) and 10 non-NDM as negative controls. All isolates had been previously characterized by whole-genome sequencing, with resistance mechanisms confirmed using CARD and ResFinder databases. RESULTS: Distinct subtype-specific amplification patterns were observed based on ΔCt values (VIC Ct minus FAM Ct). NDM-1 isolates showed minimal variation between channels at both positions (mean ΔCt 0.15 ± 0.20 at 389; 0.05 ± 0.10 at 460). NDM-14 displayed a marked shift at position 389 (mean ΔCt 4.2 ± 0.5) with negligible differences at 460. In contrast, NDM-5 consistently showed VIC signal dropout at position 460 while maintaining minimal ΔCt at 389 (0.05 ± 0.15). All non-NDM isolates tested negative. CONCLUSIONS: This assay enables rapid and accurate discrimination of key blaNDM variants within a defined epidemiological context. It provides a practical alternative to sequencing-based methods for real-time surveillance and outbreak management. Its implementation may facilitate early detection of high-risk clones, particularly in regions affected by emerging variants such as NDM-14, and support targeted infection control strategies.

来源:Clin Microbiol Infect,查看原文。版权归原作者所有。

引用

  1. García Martínez de Artola D, Palacios Clar C, Mateo León C, et al. Rapid molecular differentiation of key New Delhi metallo-β-lactamase variants in a setting with emerging high-risk clones. Clin Microbiol Infect. 2026. PMID: 42235639. doi:10.1016/j.cmi.2026.05.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。