文献速递结核与非结核分枝杆菌

唾液与口腔拭子分子检测对肺结核的诊断准确性

Diagnostic Accuracy of Molecular Testing on Saliva and Oral Swabs for Pulmonary Tuberculosis.
PubMed 文献 · Clin Infect Dis · 2026-01-01

在哥伦比亚基层医疗中心的前瞻性队列中嵌套病例对照研究,对95例培养确诊肺结核及95例匹配培养阴性对照的唾液和口腔拭子行Xpert MTB/RIF Ultra检测。唾液敏感度90.5%、特异度95.8%,拭子敏感度71.6%、特异度99%,唾液敏感度显著高于拭子,且超过WHO≥80%目标。

要点

  • 唾液Xpert Ultra检测肺结核敏感度90.5%、特异度95.8%,优于口腔拭子。
  • 唾液敏感度超过WHO对低复杂度非痰TB诊断试验≥80%的目标。
  • 唾液与拭子采集接受度均超过95%。

核心结论

  • 唾液和口腔拭子分子检测对培养确诊肺结核均具高敏感度和特异度,唾液敏感度显著优于拭子并超过WHO≥80%目标。

研究设计与样本

  • 在哥伦比亚基层医疗中心前瞻性队列中嵌套1:1发病率密度采样的病例对照研究,纳入成人和儿童,比较唾液与尼龙植绒口腔拭子Xpert MTB/RIF Ultra检测与痰培养。

主要发现

  • 唾液敏感度90.5%(95%CI 82.8-95.6),特异度95.8%(95%CI 89.6-98.8)。
  • 拭子敏感度71.6%(95%CI 61.4-80.4),特异度99%(95%CI 94.3-100)。
  • 唾液敏感度较拭子绝对提高18.9%(95%CI +10.0至+27.9,P<.001),特异度差异无统计学意义(-3.2%,95%CI -7.7至+1.4,P=.25)。
  • 超过95%的参与者认为唾液和拭子采集过程可接受。

临床怎么用

  • 在需要非痰样本诊断肺结核时,唾液Xpert MTB/RIF Ultra可作为高敏感度选项,口腔拭子敏感度较低但特异度极高。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rapid, accurate, nonsputum tests are needed to close gaps in tuberculosis (TB) detection. We evaluated the diagnostic performance of molecular testing on saliva and oral swabs. METHODS: We conducted a nested case-control study with 1:1 incidence-density sampling within a prospective cohort of adults and children undergoing evaluation for pulmonary TB at primary care centers in Colombia (July 2023-August 2024). Participants provided a sputum sample for liquid mycobacterial culture and paired saliva and nylon-flocked oral swabs for storage at -80°C. A microbiologist blinded to clinical and culture data performed Xpert MTB/RIF Ultra on thawed saliva and on swab eluate, each mixed 1:1 with sample reagent. We calculated the sensitivity and specificity of saliva and swab against sputum culture and compared them using McNemar's test. RESULTS: Among 648 enrolled participants, we tested saliva and swabs from all 95 individuals with culture-confirmed TB and 95 matched culture-negative controls (n = 190). Saliva sensitivity was 90.5% (95% confidence interval [CI], 82.8-95.6), and specificity was 95.8% (95% CI, 89.6-98.8). Swab sensitivity was 71.6% (95% CI, 61.4-80.4), and specificity was 99% (95% CI, 94.3-100). Saliva sensitivity exceeded that of swab by an absolute difference of 18.9% (95% CI, +10.0 to +27.9, P < .001), but there was no significant difference in specificity (-3.2%, 95% CI, -7.7 to +1.4, P = .25). Over 95% of participants found saliva and swab collection procedures acceptable. CONCLUSIONS: Both saliva and swabs were highly sensitive and specific for culture-confirmed pulmonary TB. Saliva sensitivity exceeded the World Health Organization's ≥80% target for a low-complexity, nonsputum TB diagnostic test.

来源:Clin Infect Dis,查看原文。版权归原作者所有。

引用

  1. Vargas DA, Fuertes-Bucheli JF, Sanchez-Hidalgo A, et al. Diagnostic Accuracy of Molecular Testing on Saliva and Oral Swabs for Pulmonary Tuberculosis. Clin Infect Dis. 2026. PMID: 41817395. doi:10.1093/cid/ciag055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。