文献速递细菌感染、耐药与抗菌药物

纸片扩散法、MIC试条与肉汤微量稀释法检测422株金黄色葡萄球菌对依拉环素敏感性的比较(采用ChinaCAST折点)

Comparison of disk diffusion, MIC test strip and broth microdilution for eravacycline susceptibility testing of 422 Staphylococcus aureus isolates using ChinaCAST breakpoints.
PubMed 文献 · J Antimicrob Chemother · 2026-01-01

该研究以肉汤微量稀释法(BMD)为参考,采用纸片扩散法(DD)和MIC试条(MTS)检测422株金黄色葡萄球菌(256株MSSA和166株MRSA)对依拉环素的敏感性,折点遵循ChinaCAST标准。结果显示DD与BMD的类别一致率(CA)为98.1%,MTS的CA为96.7%;MTS的主要误差(VME)为3.3%,DD的VME为0.7%。结论认为在本研究条件下DD与BMD一致性极好,可作为常规药敏检测的替代方法。

要点

  • 以BMD为参考,DD的CA为98.1%,MTS的CA为96.7%。
  • MRSA是VME的主要来源:MTS为7.8%,DD为1.8%。
  • DD与BMD一致性极好(κ=0.85),MTS一致性良好(κ=0.64)。

核心结论

  • 在本研究条件下,纸片扩散法与肉汤微量稀释法类别一致率极好,可作为常规实验室检测依拉环素敏感性的替代方法。

研究设计与样本

  • 以肉汤微量稀释法为参考方法,采用纸片扩散法和MIC试条检测422株金黄色葡萄球菌(256株MSSA和166株MRSA)。
  • 依拉环素判读折点遵循ChinaCAST标准(MIC≤0.25 mg/L或抑菌圈直径≥20 mm为敏感)。

主要发现

  • 依拉环素敏感率:BMD为93.6%,MTS为96.9%,DD为93.1%。
  • 与BMD相比,MTS的CA为96.7%、EA为63.0%、VME为3.3%;DD的CA为98.1%、ME为1.2%、VME为0.7%。
  • 分层分析显示MRSA是VME的主要来源(MTS为7.8%,DD为1.8%)。
  • DD与BMD一致性极好(κ=0.85,95%CI 0.74-0.95),MTS一致性良好(κ=0.64,95%CI 0.46-0.81)。

关键数值与推荐

  • 依拉环素敏感性判读采用ChinaCAST标准:MIC≤0.25 mg/L或抑菌圈直径≥20 mm为敏感。
  • 纸片扩散法与BMD的CA为98.1%,ME为1.2%,VME为0.7%。
  • MIC试条与BMD的CA为96.7%,EA为63.0%,VME为3.3%。

临床怎么用

  • 在常规实验室中,纸片扩散法可作为检测金黄色葡萄球菌对依拉环素敏感性的替代方法。
  • 对MRSA菌株,无论采用MTS还是DD,均需注意VME风险,必要时用BMD确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the reliability of different antimicrobial-susceptibility testing methods for determining the susceptibility of Staphylococcus aureus to eravacycline. METHODS: Using broth microdilution (BMD) as the reference method, disk diffusion (DD) and MIC test strips (MTS) were employed to test 422 S. aureus isolates (256 MSSA and 166 MRSA). Interpretive breakpoints for eravacycline followed the ChinaCAST criteria (MIC ≤ 0.25 mg/L or inhibition zone diameter ≥ 20 mm = susceptible). BMD results were used to calculate categorical agreement (CA), essential agreement (EA), major errors (ME), and very major errors (VME) for each comparator method. RESULTS: The susceptibility rates to eravacycline were 93.6% (BMD), 96.9% (MTS) and 93.1% (DD). Compared with BMD, MTS yielded CA 96.7%, EA 63.0% and VME 3.3%, whereas DD showed CA 98.1%, ME 1.2% and VME 0.7%. Stratified analysis revealed that MRSA was the main source of VME (7.8% for MTS and 1.8% for DD). Disk diffusion showed excellent agreement with BMD (κ = 0.85, 95% CI 0.74-0.95), whereas MTS yielded good agreement (κ = 0.64, 95% CI 0.46-0.81). CONCLUSION: Under the conditions of this study, disk diffusion demonstrated excellent categorical agreement with BMD and can serve as an alternative method for routine laboratory detection of eravacycline susceptibility.

来源:J Antimicrob Chemother,查看原文。版权归原作者所有。

引用

  1. Wang X, Yin X, Liu Y, et al. Comparison of disk diffusion, MIC test strip and broth microdilution for eravacycline susceptibility testing of 422 Staphylococcus aureus isolates using ChinaCAST breakpoints. J Antimicrob Chemother. 2026. PMID: 41549658. doi:10.1093/jac/dkaf502

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。