文献速递细菌感染、耐药与抗菌药物医院感染防控

熟练护理机构废水中碳青霉烯耐药菌的检测

Detection of Carbapenem-Resistant Bacteria in Skilled Nursing Facility Wastewater.
PubMed 文献 · J Infect Dis · 2026-01-01

该研究在美国佐治亚州三家熟练护理机构(SNF)进行为期六个月的每周废水采样,采用培养和PCR方法筛查碳青霉烯耐药菌及碳青霉烯酶基因,并用全基因组测序确认。结果在每家机构均检出临床相关和环境/机会性CR细菌,A和C机构分离株中仅检出blaKPC,PCR与WGS完全一致。

要点

  • 废水监测可早期发现SNF中循环或新出现的碳青霉烯耐药菌。
  • 培养与PCR联用可筛查常见碳青霉烯酶基因,WGS可确认所有耐药基因。
  • 三家SNF废水中均检出临床相关CR细菌,包括不动杆菌和肠杆菌复合群。

核心结论

  • 废水监测结合培养、PCR和测序可用于发现 healthcare 设施中碳青霉烯耐药菌,提供概念验证。

研究设计与样本

  • 对美国佐治亚州三家熟练护理机构每周采集废水 effluents,持续六个月,共检测73份富集废水样本。
  • 使用选择性显色培养基筛查目标CR细菌,采用培养依赖和PCR方法检测常见碳青霉烯酶基因,并用WGS鉴定分离株所有耐药基因。

主要发现

  • 共鉴定209株细菌,涵盖超过20个属。
  • 三家SNF均检出临床相关CR细菌(鲍曼不动杆菌复合群、阴沟肠杆菌复合群、屎肠球菌、寡养单胞菌属)及环境/机会性CR细菌(丛毛单胞菌属、潘多拉菌属、恶臭假单胞菌群)。
  • A机构34株分离株中9株(26.5%)检出blaKPC,C机构123株中14株(11.4%)检出blaKPC;B机构无PCR阳性结果。
  • WGS与PCR筛查结果100%一致。

关键数值与推荐

  • PCR筛查基因为blaKPC、blaNDM、blaVIM、blaOXA-48-like和blaIMP。
  • A机构blaKPC阳性9/34(26.5%),C机构blaKPC阳性14/123(11.4%),B机构无阳性。

临床怎么用

  • 可将废水监测作为SNF中碳青霉烯耐药菌早期预警的补充工具。
  • 培养与PCR联合可用于筛查常见碳青霉烯酶基因,WGS用于确认。

局限性

  • 研究仅在三家SNF进行,样本量和地域有限。
  • 仅筛查了五种常见碳青霉烯酶基因,未覆盖其他耐药机制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Wastewater surveillance at healthcare facilities for carbapenem-resistant (CR) bacteria harboring carbapenemase genes could result in earlier detection of circulating or emerging antimicrobial resistance (AR) threats. However, knowledge gaps exist regarding the CR bacterial community and carbapenemase genes present in facility wastewater and plumbing, which need to be addressed. METHODS: Wastewater effluent samples from three skilled nursing facilities (SNFs) (Georgia, USA) were collected weekly over six months. Selective chromogenic media were examined for their performance in screening the samples for targeted CR bacteria. Culture-dependent and culture-independent methods (ie, PCR) were applied to enriched wastewater samples (n = 73) to screen isolates and pooled samples for the most common carbapenemase genes circulating in the United States (blaKPC, blaNDM, blaVIM, blaOXA-48-like, and blaIMP), and method sensitivity was compared. Whole genome sequencing (WGS) was used to identify all AR genes present in isolates. RESULTS: Bacteria (n = 209 isolates) were identified using MALDI-TOF and included >20 different genera. Clinically relevant (Acinetobacter baumannii complex, Enterobacter cloacae complex, Enterococcus faecium, Stenotrophomonas spp.) and environmental/opportunistic (Comamonas spp., Pandoraea spp., Pseudomonas putida group) CR bacteria were identified in each of the three SNFs. In Facility A and C, only blaKPC was detected in 9 (26.5%) of 34 and 14 (11.4%) of 123 recovered isolates, respectively. There were no PCR-positive results in Facility B. WGS confirmed the presence or absence of all genes screened by PCR (100% concordance). CONCLUSIONS: These data provide a proof-of-concept and insights into CR bacteria present in healthcare facility wastewater using culture, PCR, and sequencing methods.

来源:J Infect Dis,查看原文。版权归原作者所有。

引用

  1. Lenz S, Biswas S, Terry I, et al. Detection of Carbapenem-Resistant Bacteria in Skilled Nursing Facility Wastewater. J Infect Dis. 2026. PMID: 41251486. doi:10.1093/infdis/jiaf534

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。