瑞典与法国假体关节感染表皮葡萄球菌耐药及种群结构
该研究纳入瑞典中部138例和法国里昂53例假体关节感染患者的表皮葡萄球菌分离株进行基因组分析,发现两国均以高耐药医院适应谱系为主,但谱系分布和耐药基因携带存在显著地区差异。
要点
- ST2谱系在瑞典占比43%显著高于法国11%,ST215仅见于瑞典占25%。
- 法国分离株中链阳菌素耐药基因(vatB、vgaA、vgaB)占26%,显著高于瑞典的2%。
- erm(C)基因在法国分离株中占77%,高于瑞典的55%;fusB基因法国66%,瑞典39%。
核心结论
- 两国假体关节感染表皮葡萄球菌均以高耐药医院适应谱系为主,但谱系分布和特定耐药基因流行率存在显著地区差异,提示该菌对地区特异性抗生素使用存在局部适应。
研究设计与样本
- 研究纳入191株临床表皮葡萄球菌分离株的基因组序列数据,来自瑞典中部2007-16年138例和法国里昂地区2015-20年53例假体关节感染患者。
主要发现
- ST2谱系在瑞典显著更常见(43% vs 法国11%),ST5和ST87在法国更常见(55% vs 瑞典10%),ST215仅见于瑞典(25%)。
- 链阳菌素耐药基因(vatB、vgaA、vgaB)在法国分离株中占26%,显著高于瑞典的2%,且存在于所有ST87分离株和20%的法国ST5分离株中。
- erm(C)基因在法国分离株中占77%,瑞典占55%;fusB基因法国占66%,瑞典占39%。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND OBJECTIVES: Staphylococcus epidermidis is a major cause of prosthetic joint infections (PJIs). Multidrug resistant (MDR), hospital-adapted clones constitute most cases globally, though regional differences in lineage dissemination likely exist. The aim was to explore the population structure of S. epidermidis from PJIs in Sweden and France, with a focus on the presence of antimicrobial resistance (AMR). METHODS: This study included genome sequence data from 191 clinical S. epidermidis isolates collected from patients with PJI in central Sweden (2007-16; n = 138) and the Lyon region in France (2015-20; n = 53). RESULTS: Hospital-adapted lineages with a high burden of AMR dominated the cases in both countries. However, the ST2 lineage was significantly more prevalent in Sweden (43% versus 11% in France), while ST5 and ST87 were more common in France (55% versus 10% in Sweden). ST215 was only present in Sweden (25%). A significantly higher prevalence of streptogramin resistance genes [vat(B), vga(A), vga(B)] was found in French (26%) versus Swedish (2%) isolates. These genes were present in all ST87 isolates and in 20% of the French ST5 isolates. The erm(C) gene (resistance to streptogramin A, macrolides and lincosamides) was also more common in the French isolates (77% versus 55% of Swedish isolates), and so was the fusidic acid resistance gene fusB (France: 66%, Sweden: 39%). CONCLUSIONS: This study highlights significant regional differences in S. epidermidis variants causing PJI. Despite similar MDR levels, certain AMR genes, particularly those related to streptogramin resistance, were significantly more prevalent among French isolates. This suggests that S. epidermidis undergoes local adaptation to region-specific antibiotic usage.
引用
- Edslev SM, Laurent F, Månsson E, et al. Antibiotic resistance and population structure of Staphylococcus epidermidis from prosthetic joint infections in Sweden and France. J Antimicrob Chemother. 2025. PMID: 40459065. doi:10.1093/jac/dkaf166
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。