两种指尖血检用于成人肺结核症状分诊的诊断准确性研究
本研究为前瞻性多中心诊断准确性研究,纳入冈比亚、南非、乌干达和越南的1262名有肺结核症状的参与者,评估Xpert-HR和MBT两种指尖血检。结果显示Xpert-HR的AUROC为0.92,敏感性92.8%,特异性62.5%;MBT的AUROC为0.91,敏感性91.4%,特异性73.2%。MBT达到了世界卫生组织分诊检测的目标产品概况。
要点
- Xpert-HR在cutoff≤-1.275时敏感性92.8%、特异性62.5%、NPV 95.9%。
- MBT在cutoff≥0.42时敏感性91.4%、特异性73.2%、NPV 96.4%。
- MBT符合WHO分诊检测目标产品概况,Xpert-HR和MBT均有前景。
核心结论
- Xpert-HR和MBT均为有前景的非痰液即时分诊检测。
- MBT达到了世界卫生组织分诊检测的目标产品概况,提示应进一步开发。
研究设计与样本
- 前瞻性诊断准确性研究,连续纳入冈比亚、南非、乌干达和越南的1262名12-70岁、咳嗽>2周且有另一种结核可疑症状的参与者。
- 采用复合参考标准(胸片、症状缓解和痰微生物学结果),使用训练-测试集方法在90%敏感性下评估cutoff特异性。
主要发现
- Xpert-HR在cutoff≤-1.275时AUROC 0.92,敏感性92.8%,特异性62.5%,PPV 47.9%,NPV 95.9%。
- MBT在cutoff≥0.42时AUROC 0.91,敏感性91.4%,特异性73.2%,PPV 52.0%,NPV 96.4%。
关键数值与推荐
- Xpert-HR cutoff≤-1.275,AUROC 0.92,敏感性92.8%,特异性62.5%。
- MBT cutoff≥0.42,AUROC 0.91,敏感性91.4%,特异性73.2%。
临床怎么用
- Xpert-HR和MBT可作为非痰液即时分诊检测用于有肺结核症状的成人。
- MBT达到WHO分诊检测目标产品概况,提示可进一步开发。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Non-sputum-based, point-of-care triage tests for pulmonary tuberculosis could enhance tuberculosis diagnostic programs. We assessed the diagnostic accuracy of 2 finger-stick blood tests: the Cepheid 3 gene host-response cartridge (Xpert-HR), which measures 3 host messenger RNA transcripts, and the 3-host protein multibiomarker test (MBT). METHODS: We performed a prospective diagnostic accuracy study of consecutive participants with symptoms compatible with pulmonary tuberculosis in The Gambia, South Africa, Uganda, and Vietnam. A composite reference standard for active pulmonary tuberculosis incorporated chest radiography, symptom resolution, and sputum microbiological test results. A training-test set approach was used to evaluate test cutoff specificities at 90% sensitivity. RESULTS: Between 1 November 2020 and 1 May 2023, we screened 1262 participants aged 12-70 years with cough lasting >2 weeks and another symptom suggestive of tuberculosis. Of those who were classifiable by reference tests, 1154 participants had evaluable Xpert-HR results and 961 had evaluable MBT results. Xpert-HR had an area under the receiver operating characteristic (AUROC) curve of 0.92 at a cutoff of -1.275 or below, with a sensitivity of 92.8%, specificity of 62.5%, positive predictive value of 47.9%, and negative predictive value of 95.9%. The MBT had an AUROC of 0.91 at a cutoff of ≥0.42, with a sensitivity of 91.4%, specificity of 73.2%, positive predictive value of 52.0%, and negative predictive value of 96.4%. CONCLUSIONS: Our results show that both Xpert-HR and the MBT are promising non-sputum-based point-of-care tests. The MBT met the World Health Organization target product profile for a triage test, which suggests it should be further developed.
引用
- Sutherland JS, van der Spuy GD, Shaw JA, et al. Performance of 2 Finger-Stick Blood Tests to Triage Adults With Symptoms of Pulmonary Tuberculosis: A Prospective Multisite Diagnostic Accuracy Study. Clin Infect Dis. 2025. PMID: 40237453. doi:10.1093/cid/ciaf105
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。